30259-0-0212
Page 42
SETTING
°
F /
°
C SCALE
The factory setting for temperature is
°
F.
To change this setting to
°
C,
first
• Press the
ON
key and the
OFF
key on the transmitter at the
same time this will change from
°
F to
°
C. Follow this same proce
-
dure to change from
°
C back to
°
F.
MANUAL FUNCTION
To operate the system in the manual “MODE” does the following.
ON OPERATION
Press the ON
key the fireplace flame will come on. During this time
the LCD screen will show ON, after 3 seconds the LCD screen will
default to display room temperature and the word TEMP will show.
(Flame icon will appear on LCD screen in on mode)
OFF OPERATION
Press the OFF key the fireplace flame will shut off. During this time
the LCD screen will show OF, after 3 seconds the LCD screen will
default to display room temperature and the word “TEMP” will also
show on the screen.
THERMOSTAT FUNCTION
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled when
the transmitter is in the THERMOSTAT mode (The word
ROOM must
be displayed on the screen
). To set the THERMOSTAT MODE and
DESIRED room temperature,
Press the MODE
key until the LCD screen shows the word
ROOM
,
then the remote is in the thermostatic mode.
Press and hold the
SET
key until the desired set temperature is
reached. (By pressing and holding the set key the LCD screen set
numbers will increase from 45
°
to 99
°
then restart over at 45
°
) Next
release the SET
key. The LCD screen will display the set temperature
for 3 seconds and the LCD screen will flash the set temperature for 3
seconds, then the LCD screen will default to display the room tem
-
perature.
TO CHANGE THE SET TEMPERATURE
Press and hold the
SET
key until the desired set temperature is
reached. (By pressing and holding the set key the LCD screen set
numbers will increase from 45
°
to 99
°
then restart over at 45
°
) Next
release the SET key. The LCD screen will display the set temperature
for 3 seconds, then will flash the set temperature for 3 seconds, then
the LCD screen will default to display the room temperature.
Press the MODE
key to disengage the thermostat mode. The word
ROOM on the LCD screen will not show when the thermostat is not in
operation.
NOTE: The highest SET temperature is 99
°
Fahrenheit
(32
°
Cel-
sius
) and the lowest temperature is (45
°
Fahrenheit
(6
°
Celsius
).
FRBTC REMOTE INSTRUCTIONS