30259-0-0212
Page 12
VENT ADAPTOR KITS
The Vent Adaptor Kits provide a transition from the fireplace to the
flue and inlet pipes. The Single Flue Horizontal Vent Kit (PVVK-
FC) provides a transition for the flue piping. No cement is required
to attach the adaptor to the fireplace. When installing the flue pip
-
ing, use the appropriate primer and cement to permanently bond
the joints and pipes. Colinear Adaptor (part number PVCA) pro
-
vides a transition for the inlet air.
See Page 16.
THREADED
FLUE CONNECTOR
FLUE ADAPTOR
INSTALL FOAM GASKET
FLUE CONNECTOR
O-RING
Figure 6
Figure 5
Available from Empire Comfort Systems, Inc.
PVVK-CFA FLEX VENT KIT
The PVVK-CFA Flex Vent Kit is a flexible vent hose that is 42” in length. The flex vent kit will be used when installing a
Mantis into an existing fireplace. The flex vent kit can be cut down, but can only be cut from one end.
Cement PVC Joints
Cut End
Cement PVC Joints
Once length is determined, install two (2) 10 x 1/2” screws into the adaptor assembly to secure the adaptor assembly to
the flex hose. Using PVC cement, cement all PVC joints of the flex vent kit to the remaining PVC vent run.
VENTING REQUIREMENTS
6” MIN.
12” MAX.
SUPPORT
OUTSIDE
WALL
1/2”
ARMAFLEX
INSULATION OR
EQUIVALENT
(IF REQUIRED)
12” ABOVE
MAXIMUM
EXPECTED
SNOW LEVEL
Figure 4
Vent Freezing Protection
When the vent pipe is exposed to temperatures below freezing
(i.e. when it passes through unheated spaces, chimneys, etc.) The
pipe must be insulated with 1/2 inch thick sponge rubber insula
-
tion, Armaflex-type insulation or equivalent. Insulating pipe is im
-
portant to avoid condensate icing.
For proper operation, the flue exhaust must extend 6 inches from
the outside wall before applying an elbow.