Empire Comfort Systems ONI-24-2 Скачать руководство пользователя страница 7

28096-23-1016

Page 7

This series is design certified in accordance with American National Standard/CSA Standard Z21.97 Outdoor Fireplace, respectively, by 

the Canadian Standards Association as a Vented Decorative Appliance and should be installed according to these instructions. 

any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on 

the rating plate is the responsibility of the person and company making the change.
Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

General InForMatIon

Gas Inlet ONR/ONI Models

3/8" (9.5mm)

accessories for onr Models

Battery Operated Remote Control

FRBC

Wall Switch

FWS

Minimum dimensions For solid Fuel Burning Fireplaces

Model

a

B

c

d

ONR-24

28"

15 

9/16

"

34 

5/16

"

24 

3/16

"

ONI-24

28"

15 

9/16

"

34 

5/16

"

24 

3/16

"

ONR-30

32"

15 

9/16

"

38 

5/16

"

24 

3/16

"

ONI-30

32"

15 

9/16

"

38 

5/16

"

24 

3/16

"

The dimensions shown and defined in the fireplace instructions are 

minimum clearances to maintain in installing this heater. Left and 

right clearances are determined when facing the front of the heater.
"A" dimension includes module cover.

Glass doors

Make sure that glass doors are open during all operations of 

the logset. The opening of the glass door frame should be the 

dimension used for the minimum front opening of the firebox.

Follow these instructions to ensure safe installation.

Failure to follow instructions exactly can create a fire hazard.

clearances

2.  Ventilation opening(s) shall be provided at floor 

level and shall have a total free area of not less 

than 1/2 square inch per pound (3.2 sq. cm/kg) of 

stored fuel capacity and not less than a total free 

area of 10 square inches (64.5 sq. cm). If ventila

-

tion openings at floor level are in a side alll, there 

shall be at least two openings. The bottom of the 

openings shall be at floor level and the upper edge 

no more than 5 inches (127 mm) above the floor. 

The openings shall be equally sized, spaced at 180 

degrees (3.14 rad) and unobstructed.

3.  Every opening shall have minimum dimensions so 

as to permit the entrance of a 1/8 inch (3.2 mm) 

diameter rod.

IntroductIon

• 

Cylinder valves shall be readily accessible for hand opera-

tion. A door on the enclosure to gain access to the cylinder 

valves is acceptable, provided it is non-locking and can be 

opened without the use of tools.

• 

There shall be a minimum clearance of 2 inches (51 mm) 

between the lower surface of the floor of the LP-gas supply 

cylinder enclosure and the ground.

• 

The design of the appliance shall be such that (1) the LP-gas 

supply cylinder(s) can be connected, disconnected and the 

connections inspected and tested outside the cylinder en-

closure; and (2) those connections which could be disturbed 

when installing the cylinder(s) in the enclosure can be leak 

tested inside the enclosure;

Содержание ONI-24-2

Страница 1: ...in the vicinity of this or any other appliance DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this app...

Страница 2: ...stics 14 Cleaning and Servicing 14 ONR 24 30 Wiring 15 Remote Control Installation and Operation 16 Troubleshooting 17 Parts View List 18 Master Parts Distributor List 19 How Tor Order Repair Parts 19...

Страница 3: ...hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Addresses...

Страница 4: ...in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may strati...

Страница 5: ...ed Porch Installation The fireplace may be installed safely and is design certified by CSA to be installed in a screen porch with the following guidelines Minimum Porch Area 96 sq feet 9 sq m Minimum...

Страница 6: ...inches water column 10 for LP and 3 5 for NAT For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator the appliance and its individual shutoff valve must be...

Страница 7: ...ed for the minimum front opening of the firebox Follow these instructions to ensure safe installation Failure to follow instructions exactly can create a fire hazard CLEARANCES 2 Ventilation opening s...

Страница 8: ...lity for proper orifice size identification For Canadian high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change When ins...

Страница 9: ...by the authority havingjurisdiction ThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length Figure 2 Pressure Testing of the Gas Supply System 1 To check t...

Страница 10: ...nd will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft b...

Страница 11: ...art has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING...

Страница 12: ...CONTROL VALVE ELECTRONIC CONTROL MODULE AF 4000 B P RED BLACK BLACK BROWN RED ORANGE N A CUSTOMER PROVIDED WALL SWITCH CONTROL MODULE SHIELD GROMMETS SECURE SHIELD TO VALVE WITH TWO SCREWS ELECTRONIC...

Страница 13: ...A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next...

Страница 14: ...ontrol compartment logs and burner area surrounding the logs clean The logs can get very hoT Handle only when cool Always keep the appliance area clear and free from combustible materials gasoline and...

Страница 15: ...valve regulator controls the burner pressure which should be checked at the pressure test point Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test poi...

Страница 16: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Страница 17: ...wires may be grounded Remove wall switch wires from valve terminals if pilot now stays lit trace wall switch wiring for ground May be grounded to appliance or gas supply Check thermopile with millivol...

Страница 18: ...e 6 27932 27932 27932 27932 Burner Support Welded Assembly Right 8 R10810 R10810 R10408 R10408 Valve LP 8 R12005 R12005 R10407 R10407 Valve NAT 9 28393 28393 Piezo Bracket 10 R9761 R9761 Piezo 11 3503...

Страница 19: ...n be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number a...

Страница 20: ...nce for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from...

Отзывы: