background image

42724-0-1120

Page 14

Empire Comfort Systems Inc. • Belleville, IL

PARTS LIST

Index Number

Part Number

Description

Quantity

1

42720

Termination Cover Plate

1

2

42648

Screen

1

3

42726

Termination Assembly

1

4

42719

Termination, Back Plate

1

5

42721

Air Duct

2

6

42760

Inlet Collar

1

7

R13212

Blower, P-Tech TTB-3018

1

8

42716

Mounting Plate

1

9

R10856

Spacer, Vibration

4

10

42715

Base, Blower

1

N/S

R13145

Wire Harness, 2 Feet

1

N/S

R13221

Diverter Connector, 6 X 6 X 6 Y-Branch

1

N/S

R13222

Adapter, 6 Inch Flex

1

N/S

R13223

Clamp, 7 Inch Diameter Gear Clamp

4

N/S

R4186

Rheostat

1

N/S

R4192

Knob, Rheostat

1

N/S

42727

Collar, 6 Inch Diameter

2

N/S

42728

Flange, Collar

2

N/S

R11243

Cover, Plate, Junction Box

1

N/S

R1563

Wirenut, Black

2

N/S

R3490

Junction Box

1

N/S

B101569

Screw, # 10 X ½" Self Drilling SS

3

N/S

R11686

Drywall Screw, # 8 X 1"

19

N/S

R2737

Screw, # 10 X ½" HWH

26

N/S = Not Shown

Содержание HMFA-1

Страница 1: ...ARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any...

Страница 2: ...central furnaces include make up air dampers If a make up air damper is included with the furnace check the damper for proper function and operation There are variations in central furnace make up dam...

Страница 3: ...LENGTH REQUIRED ALL APPLICATIONS REQUIRE A MINIMUM 7 LENGTH OF FLEX VENT FROM THE Y CONNECTOR TO THE BLOWER NO MINIMUM LENGTH REQUIRED NOTE Flex venting from kit SD6DFA25 CAUTION Due to sharp edges an...

Страница 4: ...VENT DUCT WORK VERTICAL ALL APPLICATIONS REQUIRE A MINIMUM 7 LENGTH OF FLEX VENT FROM Y CONNECTOR TO THE BLOWER ALL APPLICATIONS REQUIRE A MINIMUM 7 LENGTH OF FLEX VENT FROM THE Y CONNECTOR TO THE BLO...

Страница 5: ...or the junction box field wiring and internal placement of the rheostat to control the HMFA should be made Refer to electrical connections on page 10 4 The framed opening for installation of the HMFA...

Страница 6: ...4 1 2 OFFSET FLANGE TO BE FLUSH WITH INSIDE WALL AND SECURED BACK EDGE OF BLOWER BASE BRACKET TO BE MOUNTED FLUSH TO THE INSIDE WALL VENT CONNECTION RIGHT SIDE Figure 5a Figure 5b LEFT SIDE VENT CONNE...

Страница 7: ...ns based on the particular fireplace model you have NOTE Collar Flange Hand bend tabs to be bent down on DVLL72 only 4 DVCT SERIES 1 DVLL 36 48 60 2 DVLL72 3 8 DVL 36 46 4 DVCT SERIES 1 DVLL 36 48 60...

Страница 8: ...making sure the bottom of the collars are touching the inner heat shield then install 4 10 X screws to secure each collar assembly See figure 10 INSTALLATION OF THE FLEX VENTING 11 Plan out the locati...

Страница 9: ...adapter installed in step 10 Secure each flex vent section to the collars on top of the fireplace with a 7 diameter gear clamp See Figure 12 15 Attach and secure the Y adapter to the two flex section...

Страница 10: ...ied electrician 2 Flexible Conduit Wire Harness 120 VAC Power In From Rheostat Wall Switch To Fireplace Connections Figure 14 18 The electrician is responsible for performing all wiring from the blowe...

Страница 11: ...Figure 18 Figure 18 23 Install the cut end of the Air Duct over the Blower outlet See Figure 19 24 Check to see if the flanges of the Air Duct are flush with the bottom inside flange of the Outer Ter...

Страница 12: ...e Outer Cover then place the Outer Cover into the Outer Termination frame Using 4 10 X screws secure the Outer Cover to complete the installation See Figure 22 BACK PLATE OUTER TERMINATION ASSEMBLY SC...

Страница 13: ...42724 0 1120 Page 13 Empire Comfort Systems Inc Belleville IL This page intentionally left blank...

Страница 14: ...1 9 R10856 Spacer Vibration 4 10 42715 Base Blower 1 N S R13145 Wire Harness 2 Feet 1 N S R13221 Diverter Connector 6 X 6 X 6 Y Branch 1 N S R13222 Adapter 6 Inch Flex 1 N S R13223 Clamp 7 Inch Diame...

Страница 15: ...42724 0 1120 Page 15 Empire Comfort Systems Inc Belleville IL Figure 23 Exploded View 1 2 3 4 5 6 7 8 9 10...

Страница 16: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Страница 17: ...ison voisine Suivre les instructions du fournisseur de gaz S il est impossible de joindre votre fournisseur de gaz appeler le service d incendie L installation et l entretien doivent tre ex cut s par...

Страница 18: ...MED OPENING WHEN BELOW TOP OF FIREPLACE FRAMED OPENING WHEN ABOVE THE TOP OF FIREPLACE 6 FLEX VENT 4 FOOT MINIMUM 4 INCHES MINIMUM CONDUIT D VACUATION FLEXIBLE DE 6 po 152 4 mm OUVERTURE LORSQU ELLE S...

Страница 19: ...GUEUR MINIMALE DE CONDUIT D VACUATION FLEXIBLE DE 7 pi 2 13 m DU RACCORD EN Y JUSQU LA SOUFFLANTE PAS DE LONGUEUR MINIMALE REQUISE REMARQUE Conduit d vacuation flexible de la trousse SD6DFA25 ATTENTIO...

Страница 20: ...M Y CONNECTOR TO THE BLOWER VERTICAL VENTED FIREPLACE ATTENTION En raison du poids de l appareil et du fait qu il pr sente des bords tranchants porter une protection oculaire appropri e et des gants p...

Страница 21: ...rh ostat pour commander le syst me HMFA Se reporter aux raccordements lectriques la page 10 4 L ouverture pour l installation du syst me HMFA est de 14 1 2 po x 14 1 2 po 368 3 mm x 368 3 mm dans tout...

Страница 22: ...GE TO BE FLUSH WITH INSIDE WALL AND SECURED BACK EDGE OF BLOWER BASE BRACKET TO BE MOUNTED FLUSH TO THE INSIDE WALL VENT CONNECTION RIGHT SIDE Figure 5a Figure 5b LEFT SIDE VENT CONNECTION Figure 5c B...

Страница 23: ...QUE Bride de collier languettes plier vers le bas manuellement sur le mod le DVLL72 seulement 4 DVCT SERIES 1 DVLL 36 48 60 2 DVLL72 3 8 DVL 36 46 4 DVCT SERIES 1 DVLL 36 48 60 2 DVLL72 3 8 DVL 36 46...

Страница 24: ...rmique interne puis visser 4 vis n 10 x 1 2 po pour fixer chaque collier Voir Figure 10 INSTALLATION DU CONDUIT D VACUATION FLEXIBLE 11 Pr parer l emplacement de l adaptateur Y Le placement de cet ada...

Страница 25: ...r l aide d un collier de serrage vis sans fin de 7 po 177 8 mm de diam tre Voir Figure 12 15 Fixer solidement l adaptateur en Y aux deux sections de conduit d vacuation flexible provenant du foyer au...

Страница 26: ...tat Wall Switch To Fireplace Connections Figure 14 18 L lectricien est responsable de la r alisation de l ensemble du c blage partir de la soufflante jusqu au rh ostat mont sur le mur Le rh ostat doit...

Страница 27: ...nduit d air sur la sortie de la soufflante Voir Figure 19 24 V rifier si les rebords du conduit d air sont align s avec le rebord interne inf rieur de l assemblage d extr mit ext rieure comme illustr...

Страница 28: ...ercle ext rieur puis placer le couvercle ext rieur dans l assemblage d extr mit ext rieure l aide de 4 vis n 10 x 1 2 po fixer le couvercle ext rieur pour terminer l installation Voir Figure 22 BACK P...

Страница 29: ...42724 0 1120 Page 13 Empire Comfort Systems Inc Belleville IL Page laiss e vierge intentionnellement...

Страница 30: ...145 Faisceau de c bles 2 pi 610 mm 1 N M R13221 Raccord en Y 6 po x 6 po x 6 po 152 4 mm x 152 4 mm x 152 4 mm 1 N M R13222 Adaptateur flexible 6 po 152 4 mm 1 N M R13223 Collier de serrage vis sans f...

Страница 31: ...42724 0 1120 Page 15 Empire Comfort Systems Inc Belleville IL Figure 23 Vue clat e 1 2 3 4 5 6 7 8 9 10...

Страница 32: ...irecomfort com Empire Comfort Systems Inc Belleville IL Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou...

Отзывы: