39359-4-0320
Page 60
REMOTE CONTROL OPERATION INSTRUCTIONS
SMART THERMOSTAT OPERATION
The Smart Thermostat function adjusts the flame height in accor
-
dance with the difference between the set point temperature and
the actual room temperatures.
As the room temperature gets closer to the set point the Smart
Function will modulate the flame down.
To activate this function, press the THERMOSTAT key until the
word “SMART” appears to the right of the temperature bulb
graphic.
To adjust the set temperature, press the UP or DOWN ARROW
keys until the desired set temperature is displayed on the LCD
screen of the Transmitter.
NOTICE:
When Smart Thermostat is activated, the manual flame
height adjustment is disabled.
Figure 85 - SMART Function Icon
Figure 86
FAN SPEED CONTROL
The speed of the fan can be controlled by the Proflame system.
The fan speed can be adjusted through six speeds.
To activate this function, use the MODE key
Figure 76a
to index
to the fan control icon.
See Figure 87.
Use the UP/DOWN ARROW keys to turn on, off or adjust fan
speed.
See Figures 76a and 88.
A single “beep” will confirm reception of the command.
Figure 87 - Fan Icon
Figure 88 - Fan Speed Control Activated
Содержание DVP48FP30
Страница 20: ...39359 4 0320 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Страница 41: ...39359 4 0320 Page 41 1 Place Log A 1 onto two pins on rear log support as shown below LOG PLACEMENT DVP 42 48...
Страница 45: ...39359 4 0320 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Страница 48: ...39359 4 0320 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 56: ...39359 4 0320 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 83: ...39359 4 0320 Page 83 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...