MAINTENANCE AND SERVICE (CONT'D)
Glass Door Installation
Figure 68
Barrier Screen Installation
Figure 69
FOR THE HOMEOWNER
Annual Inspection
•
Have the fireplace inspected annually before use.
•
More frequent inspection and cleaning may be required if the fireplace
is installed in an area exposed to pet hair or dust, or to excessive lint
from new carpeting or bedding materials.
During The Annual Checkup, The Technician Will:
•
Inspect the pilot (flame safety system) and burner(s) for proper
operation and replace any damaged parts.
•
Check the glass and gasket for proper seal.
•
Vacuum and clean any foreign debris in the firebox that is not
supposed to be there.
•
Clean Glass with a suitable fireplace glass cleaner. Abrasive cleaners
must not be used. Be careful not to scratch the glass when cleaning.
•
Check the barrier screen for fit and structural integrity.
See Figure 69.
•
Check all latches or other door retention components for proper
operation, tension, and relief mechanisms are free from obstructions.
See Figure 68.
•
Inspect the log set (if applicable) and decorative media (if applicable)
for debris or damage.
•
Freshen up the glowing embers if applicable.
•
Replace batteries in the remote transmitter and receiver if applicable.
•
Inspect the venting and vent termination cap for damage, corrosion,
sooting, or obstruction and correct if present.
•
In addition, clean and inspect the fireplace following any remodeling
work in your home.
FOR THE INSTALLER
Annual Inspection
•
Have the fireplace inspected annually before use.
• More frequent inspection and cleaning may be required if the
fireplace is installed in an area exposed to pet hair or dust, or to
excessive lint from new carpeting or bedding materials.
During The Annual Checkup, The Technician Will:
•
Inspect the pilot (flame safety system) and burner(s) for proper
operation and replace any damaged parts.
•
Test and measure the flame failure response time of the flame safety
system. It must de-energize the safety shut-off in no more than 30
seconds.
•
Vacuum and clean any foreign debris in the firebox that is not
supposed to be there.
•
Inspect and ensure that the lighting of the main burner occurs within
4 seconds of the gas valve opening. Visual inspection should match
the information illustrated in the manual. Inspect primary air openings
for blockage.
•
Check the glass and gasket for proper seal.
•
Clean Glass with a suitable fireplace glass cleaner. Abrasive cleaners
must not be used. Be careful not to scratch the glass when cleaning.
•
Check all latches or other door retention components for
proper operation, tension, and relief mechanisms are free
from obstructions.
See Figure 68.
•
Check the barrier screen for fit and structural integrity.
See Figure 69.
•
Inspect the log set (if applicable) and decorative media
(if applicable) for debris or damage.
•
Freshen up the glowing embers if applicable.
•
Replace batteries in the remote transmitter and receiver if applicable.
•
Inspect the venting and vent termination cap for damage, corrosion,
sooting, or obstruction and correct if present.
•
Check all accessible gas-carrying tubes, connections,
pipes and other components for leaks.
•
In addition, clean and inspect the fireplace following any