26930-5-1010
Page 17
Figure 23
Examples of possible venting systems using two (2) 90° elbows.
V is listed as minimum vertical dimensions and H1 + H2 is listed
as total of maximum horizontal dimensions. The maximum vertical
and horizontal distances for two (2) 90° elbows as shown in Figure
24 is 20 feet.
Attention: Refer to Figure 21 for additional venting requirements.
Figure 24
Below Grade Installation
When it is not possible to meet the required vent terminal clearances
of 12" (305mm) above grade level, a snorkel kit is recommended.
It allows installation depth down to 7" (178mm) below grade level.
The 7" (178mm) is measured from the center of the horizontal vent
pipe as it penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting
system is installed below ground, we recommend a window well
with adequate and proper drainage to be installed around the
termination area.
TYPICAL BASEMENT INSTALLATION
Figure 22
Examples of possible venting systems using one (1) 90° elbow.
Eight (8) feet is listed as minimum vertical vent run with 20 feet of
maximum horizontal vent run. Vertical dimensions are based on
centerline to centerline of pipe. Horizontal dimensions are based
on centerline of pipe to end of termination.
Firestop at
Ceiling Level
Firestop at
Ceiling Level
vENTING FIREpLACE - TOp (continued)
Lp and Nat models
Lp and Nat models
Lp and Nat models
Содержание DVP36FP3 series
Страница 44: ...26930 5 1010 Page 44 Figure 68 OPTIONAL THERMOSTAT OPTIONAL WALL SWITCH STANDING PILOT WIRING DIAGRAM...
Страница 57: ...26930 5 1010 Page 57 INTERMITTENT PILOT TROUBLESHOOTING continued...
Страница 74: ...26930 5 1010 Page 74 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 75: ...26930 5 1010 Page 75 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...