31259-3-0114
Page 28
Continue replacing components per the vent system configuration.
Be certain that each succeeding vent component is securely fitted
and locked into the preceding component in the vent system.
Reassembly and Resealing Gas Accumulation Relief System
Glass Frame Assembly and Combustion Chamber
Whenever the glass frame assembly is pivoted open by a delayed
ignition in the main burner, the glass frame assembly gaskets and
combustion chamber must be examined by a qualified service person
for damage. All damaged gaskets on the glass frame assembly and
combustion chamber must be replaced by a qualified service person.
If damage occurs to the combustion chamber, it must be replaced
by a qualified service person. Contact Empire Comfort Systems,
Inc. for replacement parts.
Vertical Through the Roof Applications
Your Gas Fireplace has been approved for:
a) Vertical installations up to 40 feet in height.
b) Two sets of 45 degree elbow offsets within these vertical
installations. From 0 to a maximum of 8 ft. a vent pipe can be
used between elbows.
c) Wall straps must be used to support offset pipe every 4'.
This application will require that you first determine the roof pitch
and use the appropriate venting components.
40’
(12.19M)
MAXIMUM
8’ (2.44M)
MAXIMUM
8’ (2.44M)
MAXIMUM
45°
45°
TYPICAL ROOF
SUPPORT
TYPICAL JOIST
SUPPORT
▲
►
◄
▲
▼
◄
▼
▲
►
◄
Figure 46
VERTICAL TERMINATION (continued)
Vertical Vent Baffle Installation
In applications without elbows (a straight vertical installation), the
use of a vertical vent baffle may be requred. The vertical vent baf-
fle is the flat piece of painted steel with eight holes located in the
instruction envelope.
1. Locate and remove the two screw to the right of the flue open-
ing.
2. Verify the flue blockage requirements to steady the flame.
Note:
40 foot vertical requires maximum blockage. 10 foot
vertical requires minimum blockage.
3. Align vertical vent baffle holes with the holes in the firebox top
and secure vent baffle with the two screw in the same holes
they were removed from in step 1.