INSTALLATION (continued)
Flush Mount Installation
The fireplace must extend 3/4” (19mm) beyond finished wall surface
when using a flush mount. Refer to Figure 13 to locate nailing flanges
on fireplace sides. Mark and drill two 1/8” holes into fireplace side to
mount each nailing flange. Use eight 1/2” hex-head screws supplied
in hardware package to attach nailing flanges to fireplace sides.
▲
Figure 13
Flush Wall Installation
1/2” (12 mm) NON- COMBUSTIBLE
NON- COMBUSTIBLE FINISHED WALL
ALL FIREPLACE METAL MUST BE
COVERED WITH NON-COMBUSTIBLE
MATERIAL ONLY
TOP OF FIREPLACE OPENING
IMPORTANT: NO FINISHING
MATERIAL OF ANY TYPE MAY
EVER OVERLAP THE OPENING
OF THE SIDES OR TOP.
GLASS WILL NOT FIT
IF IT DOES.
STANDOFF
2 X 4 OR 2 X 6
SHOWN VERTICAL
MAY BE HORIZONTAL
AND/OR DOUBLED UP
◄
▼
◄
◄
▼
▼
Figure 14
Framing and Finishing
1. Choose unit location.
2. Frame in fireplace with a header across the top. It is important
to allow for finished face when setting the depth of the frame.
3. Attach fireplace to frame.
See Figure 15.
Figure 15