background image

Page 8

R-3450

Stone Inlay Replacement of Standard Grille Top
Whenever the standard grille top is replaced with a stone inlay you must
install the top shield and heat shield, which are provided with the stone
inlay.

Installation of Optional Stone Inlay
1. Remove left grille, center grille and right grille from casing top.
2. Remove casing top from outer casing.
3. Place the casing top on a non-abrasive surface in order to protect the

porcelain finish. The exterior of the casing top should be facing the
non-abrasive surface.

4. Attach 11 5/8" x 11 5/8" top shield to the interior of the casing top

with (1) 3/8" bolt provided in hardware package.

5. Remove the (2) 1/2" hex-head screws located on the front of the heat

exchanger top. The screws are 8 3/4" apart. Do not remove the center
hex-head screw. Remove the (2) screw hole, knockouts located on
the back of the heat exchanger top. The knockouts are 8 3/4" apart.
Position the angled front on the 12" x 19 3/8" heat shield with the
front of the appliance. Align the (4) tabs with clearance holes on the
12" x 19 3/8" heat shield with the (4) screw holes on the heat
exchanger top. Attach the 12" x 19 3/8" heat shield to the heat
exchanger top with (2) 1/2" hex-head screws removed in Step 5 and
(2) 1/2" hex-head screws provided in hardware package.

6. Place the casing top onto the outer casing. The casing top nests into

the outer casing.

7. Insert center stone inlay, left stone inlay and right stone inlay into

casing top.

8. Installation of stone inlay is completed.

Parts List

Part

Part

Quantity

Description

Number

Supplied

11 5/8" x 11 5/8" Top Shield

CI-091

1

12" x 19 3/8" Heat Shield

CI-092

1

3/8" Bolt

R-3646

1

1/2" Hex-Head Screw

R-2737

4

Installation of Wire Channel Assembly (Figure 10)
The ON/OFF/REMOTE switch with harness is factory installed into the
switch box.
After the appliance housing is installed into the cast iron outer casing the
wire channel can be installed.
1. Attach switch box on the left side of casing back with (2) 10 x 1/2"

provided screws.

2. Route wires from ON/OFF/REMOTE switch within wire channel.
3. Attach wire channel on the left side of the casing back  with  (4) 10

x 1/2" provided screws.

4. Attach the black and green (wires) female push-ons to the TH/TP

and TH (two outside male tabs) terminals on gas valve.

5. Identify vent safety switch wire harness. The first wire is installed

into magnet section on gas valve. The second wire is attached to the
TH/TP terminal on gas valve. Route opposite end of vent safety
switch wire harness within (2) metal clips on exterior of rear cover.
Attach (2) 1/4" female push-ons on vent safety switch wire harness
onto (2) 1/4" male tabs on vent safety switch which is located on the
side of draft diverter.

Figure  10

Venting

1. Flue pipe must be as large as the flue collar on the draft diverter.
2. Maintain an upward slope of at least 1/4 inch (6mm) per foot of

horizontal run.

3. Run flue pipe as directly as possible with a minimum of elbows.
4. Flue pipe should extend through the wall of a chimney to be flush

with inner wall.

5. Flue pipe must be adequately supported by metal straps.
6. Single wall vent pipe may be attached directly to the draft hood of

the fireplace heater when a clearance of 2 1/2 inches (64mm) is
maintained between the single wall vent pipe and the combustible
wall of the room in which the fireplace heater is located.  Use double
wall vent pipe for clearances less than 2 1/2 inches (64mm) to
combustibles.

7. For flue pipe running through walls and roof, use B-1 [1 inch (25mm)

clearance to combustibles] vent pipe.

8. Chimneys should extend at least 2 feet (.6m) above the roof and

above any object or nearby building within 10 feet (3m).

9. Open tees should not be used in the flue pipe.

10. Appliance must not be connected to a chimney flue that is servicing

a separate solid-fuel burning appliance.

For proper venting, do not attach a 90

°

 elbow directly to draft diverter.  If

possible,  attach 2 feet (.6m) of straight vent pipe before an elbow is used.
Use of 45

°

 elbows is recommended.

Uninsulated single-wall metal pipe shall not be used outdoors in cold
climates for venting gas utilization equipment.

Ventilation and Combustion Air
Fireplace heaters shall be installed in a location in which the facilities for
ventilation permit satisfactory combustion of gas and proper venting
under normal conditions. In buildings of conventional frame, brick or
stone construction without tight storm windows and doors, infiltration is
normally adequate to provide for combustion and draft hood dilution.

Where appliances are installed in a confined space within a building, the
building being of unusually tight construction, air for combustion and
ventilation must be obtained directly from outdoors or from such spaces
that freely communicate with the outdoors. Under these conditions, the
confined space shall be provided with two permanent openings, one near
the top of the enclosure and one near the bottom; each opening shall have
a free area of not less than one square inch (6.5cm

2

) per 1,000 BTU's

(.3KW) of total input. The draft hood must be in the same atmospheric
pressure zone as the combustion air inlet to the appliance and shall be so
located so that the relief opening is accessible for checking vent operation.

Содержание CIBV-30-2

Страница 1: ...ds in the vicinity of this or any other appliance AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans le présent manuel risque de déclencher un incendie ou une explosion entraíant des dommages matériels des lésions corporelles ou la perte de vies humaines Installation ou modification consulter le manuel des usagers fourn avec ce générateur d air chaud Ne pas entreposer ni uti...

Страница 2: ...icing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment clean Installation and repair should be done by a QUALIFIED SER VICEPERSON Thefireplaceheatershouldbeinspectedbefore use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpe...

Страница 3: ...orm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old ta...

Страница 4: ...diction The installation must conform with local codes or in the absence of local codes the current National Fuel Gas Code ANSI Z223 1 NFPA 54 or CAN1 B149 Gas Appliance Installation Code Installer l appareil selon les codes ou règlements locaux ou en l absence de tels règlements selon les Codes d installation CAN CGA B149 Available from the American National Standards Institute Inc 11 West 42nd S...

Страница 5: ... do not completely tighten the two front leg pads to the casing sides with 2 3 8 bolts Attention The front leg pads can be adjusted to provide a snug fit between the casing front and the casing sides 4 Attach 4 leveling bolts to the bottom of the 4 legs 5 Align the 3 8 hole at the top of the leg with the 3 8 hole in the leg pad Attention For proper positioning of the leg to the leg pad the 2 1 1 2...

Страница 6: ...aining tabs should be positioned downward from the casing front top to the casing front bottom 11 Refer to Figure 8 attach casing front to outer casing by using the 4 retaining tabs on the casing front The 2 top retaining tabs on the casing front will be placed behind the 2 top locator tabs on the front of the casing sides The 2 bottom retaining tabs will be inserted into the 2 9 16 slots on the f...

Страница 7: ...ecure the valve cover in place during shipping The 1 Phillips head screw can be discarded 15 Attach casing front to outer casing as described in Step 11 16 Place the casing top onto the outer casing The casing top nests into the outer casing 17 Insert center grille left grille and right grille into casing top 18 Level appliance by adjusting leveling bolts 19 Assembly of cast iron outer casing stov...

Страница 8: ...2 metal clips on exterior of rear cover Attach 2 1 4 female push ons on vent safety switch wire harness onto 2 1 4 male tabs on vent safety switch which is located on the side of draft diverter Figure 10 Venting 1 Flue pipe must be as large as the flue collar on the draft diverter 2 Maintain an upward slope of at least 1 4 inch 6mm per foot of horizontal run 3 Run flue pipe as directly as possible...

Страница 9: ...ipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect Method of Installing A Tee Fitting Sediment Trap Figure 11 Pressure Testing of the Gas Supply System 1 To check the inlet pressure to the gas valve a 1 8 3mm N P T plugged tapping accessible for the test gauge connection must be placed immediately upstream of the gas supply conn...

Страница 10: ... an altitude of Orifice size Manifold Pressure Input Btu h Fuel Type Date of Conversion Converted by Cet appareil a été converti au Injecteur Pression à la tubulure d alimentation Déoit calorifique Piezo Ignitor Button The piezo ignitor button is located behind the valve cover Depressing the button causes a spark to occur at the pilot On a new installation with air in the gas line depress the piez...

Страница 11: ...he wiring chase A wire harness is attached to the ON OFF REMOTE switch The red black and green wires female push ons attach to the ON OFF REMOTE switch At the opposite end of the wire harness the black and green wires female push ons attach to the gas valve An additional green wire and the red wire which are stripped and bare will attach to the 750 millivolt wall thermostat accessory or to one of ...

Страница 12: ...manual mode You must turn the appliance ON or OFF with appropriate accessory Wall Thermostat Operation 1 Turn the ON OFF REMOTE switch on wiring chase to REMOTE position 2 Turn accessory FRBC 1 FREC 1 or FWS 1 OFF 3 Turn wall thermostat ON and set appropriate temperature Wall thermostat will cycle the appliance ON and OFF Installation of Remote Receiver Figure 17 1 Attach from left to right the sl...

Страница 13: ...ront log onto the two front pins on the base 7 Align the two alignment holes on the underside of the top log with the alignment pins on the top of front log Place the top log onto the two pins on the front log 8 Grasp bottom of glass frame push upward and insert glass frame into glass frame support top push inward and insert glass frame into glass frame guide 9 Attach two door latches to bottom of...

Страница 14: ...burner flame on or off with the appliance ON OFF rocker switch wall switch remote control kits or 750 millivolt wall thermostat NOTE The gas control valve allows you to increase or decrease the heightofthemainburnerflame Thecontrolvalvehasapressureregulator with a knob as shown in Figure 21 Rotate the knob clockwise to HI to increase the flame height and counterclockwise to LO to decrease the flam...

Страница 15: ... off all electric power to appliance if service is to be performed if applicable 3 Lower valve cover 4 Push in gas control knob slightly and turn clock wise to OFF Do not force 5 Raise valve cover TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli cable 4 Lower va...

Страница 16: ...ective Check on off switch and wires for proper connections Place jumper wires across terminal at switch if burner comes on replace defective switch If OK place jumper wires across switch wires at gas valve if burner comes on wires are faulty or connections are bad b Thermopile may not be generating sufficient milli voltage Ifthepilotflameisnotcloseenoughphysicallytothethermopile adjust the pilot ...

Страница 17: ...R 3450 Page 17 ...

Страница 18: ...NAMEL 2 R 3712 WINDOW RED ENAMEL 2 R 3720 WINDOW NAVY ENAMEL 3 R 3949 GRILL LEFT BLACK PAINT 3 R 3726 GRILL LEFT BLACK ENAMEL 3 R 3729 GRILL LEFT SAND ENAMEL 3 R 3732 GRILL LEFT GREEN ENAMEL 3 R 3735 GRILL LEFT RED ENAMEL 3 R 3738 GRILL LEFT NAVY ENAMEL 4 R 3950 GRILL CENTER BLACK PAINT 4 R 3727 GRILL CENTER BLACK ENAMEL 4 R 3730 GRILL CENTER SAND ENAMEL 4 R 3733 GRILL CENTER GREEN ENAMEL 4 R 3736...

Страница 19: ...R 3450 Page 19 ...

Страница 20: ...from blue wire on the fan control to the AUTO top tab on the switch 12 Attach 1 4 push on terminal from black wire to the OFF middle tab on the switch 13 Attach 1 4 push on terminal from white wire on the fan control to the ON bottom tab on the switch 14 Installation of optional CIB 2 blower is completed Fan Control The fan control is a non adjustable automatic type The fan control will require be...

Страница 21: ...t No No Description 1 R 1454 Brass Bushing 4 Required 2 R 1499 Rubber Grommet 4 Required 3 CI 002 Blower Housing 4 R 1517 Tinnerman Clip 4 Required 5 R 2804 A Blower Assembly 6 CI 003 Blower Housing Cover 7 R 2099 Cord Set 8 R 3767 A Wire Harness 9A CI 004 Fan Control Bracket Use with CIBV 30 CIVF 25 CIVF 25C Only 9B CI 325 Fan Control Bracket Use with CIDV 30 Only 10 R 2503 Fan Control 11 R 2805 ...

Страница 22: ...e 22 R 3450 Service Notes Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529 PH 1 800 851 3153 FAX 1 800 443 8648 E MAIL empire accessus net WEB SITE www empirecomfort com ...

Отзывы: