41117-0-0819
Page 25
VENTING FIREPLACE - TOP
WARNING
Use flue restrictor for vertically terminated fireplaces only.
Do not use for horizontally terminated fireplaces.
Figures 37 to 40
show the location and recommended opening
for the flue restrictor.
Installation of restrictor before venting is attached.
See Figure 37.
Figure 37
NOTICE:
When installing flue restrictor, install with screw pointing
downward.
For installation of the restrictor after the venting is installed,
remove (2) screws from each end of the flue baffle and set aside.
Insert the restrictor up into the flue collar and position it as shown
in
Figures 38 and 39.
Then, re-install the flue baffle.
REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
FLUE RESTRICTOR
Figure 38
REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
FLUE RESTRICTOR
Figure 39
Figure 40
A1
CENTER
OF ELB
OW
STRAIG
HT OUT
(MINIM
UM)
A2
CENTE
R OF E
LBOW
STRAIG
HT OUT
(MINIM
UM)
FIREPLACE
SERIES
HARD ELBOW DIMENSIONS
A1
B
C
D
DVLL60
54-3/4-in
5-3/8-in
7-5/8-in
10-5/8-in
FIREPLACE
SERIES
FLEX PIPE 90 DEGREE BEND
A2
B
C
D
DVLL60
54-3/4-in
5-3/5-in
7-5/8-in
10-5/8-in
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH-
THE-WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW AND 12-in RISE OFF TOP OF FIREPLACE
SEE FIGURE 44 ON PAGE 27 FOR PERMISSIBLE
HORIZONTAL AND VERTICAL RUN DIMENSIONS.
Figure 41