41368-0-0120
Page 12
CLEARANCES
CLEARANCE TO COMBUSTIBLES
Back
See Fig. 10
Side
3-in
Floor
0-in
Top Stand-off Bracket
0-in
Top Framing Edge
13-in
SEE MANTEL CHART FOR
MAXIMUM MANTEL DEPTH
13” MIN.
2” X 4” HEADER
STAND-OFF
13” (76mm) HEIGHT
ABOVE TOP OF FIREPLACE
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
BOARD
TOP FRAMING LEDGE
SEE MANTEL CHART
FOR MINIMUM HEIGHT
OF MANTEL ABOVE
UNIT OPENING
BARRIER
SCREEN/GLASS
FRONT
NOTE A: See Figure 12
for maximum mantel depth and
minimum height above fireplace.
Figure 9
8”
3”
3”
2”
NOTE: COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA
3”
Figure 10
The minimum clearance from bottom of the fireplace to ceiling is 65-in.
The minimum clearance from side of the fireplace opening to
adjacent sidewall is 8-in.
8” MIN.
(20cm)
TO BOTT
OM
OF CABINET
CEILING
TO BOTT
OM OF
VENTED OPENING
57
5/8” MIN
(146cm)
65”
MIN
(165cm)
Figure 11
MANTEL CHART
TOP EDGE OF
FIREPLACE OPENING
H
22”
34”
12”
A
3”
MINIMUM
NON-COMBUSTIBLE MA
TERIAL
ZONE
INDEX
LETTER
DISTANCE FROM
FIREPLACE OPENING
(in inches)
DISTANCE FROM
FINISHED WALL
(in inches)
A
34
12
B
34
10
C
32
8-3/8
D
30
6-5/8
E
28
5
F
26
3-3/8
G
24
1-3/4
H
22
0
Figure 12
Television Considerations
Installing a television above a fireplace has become increasingly
popular; however, the area above any fireplace gets hot and most
TV manufacturers recommend against placing their products
near a heat source.
If you install a television above this fireplace, Empire Comfort
Systems accepts no responsibility for damage or injuries. Follow
the television manufacturer’s installation instructions, including
any recommendations regarding proximity to heat sources.
If you have a TV above your fireplace, turn off the fireplace and
let it cool completely before servicing or touching any buttons on
the TV.