40916-0-0919
Page 14
INSTALLATION (CONT'D)
WARNING
Failure to position the parts in accordance with all included
pictures, diagrams and drawings, or failure to use only
parts specifically approved with this appliance may result
in property damage or personal injury.
4. Spread the rock wool over the burner. The rock wool should
be broken into fluffy quarter-sized pieces.
Figure 8
5. Place the lava rock around the burner assembly.
Figure 9
WARNING
Apply loose material (rockwool and lava rock) per instruction
manual. DO NOT apply extra material not supplied with this
appliance. All previously applied loose material (rock wool)
must be removed prior to reapplication.
CAUTION
DO NOT place rockwool or lava rock in the area of the
safety pilot assembly.
STOP!
The LKF Fiber Log Set and LPR2430 Refractory Log Set are the
only two log sets which are approved for use on these burners. DO
NOT substitute a different log set or deviate from the log place-
ment sequence.
Refer to the instructions packaged with your Decorative Gas Logs.
6. Remove all contents from the Decorative Gas Log carton.
7. Check the contents of the carton against the parts list in the
manual. Report any missing or damaged parts to your retailer.
8. Remove any and all protective wrapping from the gas logs.
9. Arrange the decorative gas logs on the burner according to
the instructions.
NOTICE:
The Commonwealth of Massachusetts requires that the
chimney flue damper, when used with decorative gas log sets, be
welded open or completely removed.