background image

 

10 

Do not connect the grounding output cable with the grounding input cable as 
this action causes a short circuit to occur. 

Audio Input Cable 

user can select the input method according to the equipment storage environment. 

 

Use RJ45 Port: 

The See Table 3 for the pin descriptions. 

  Note: 

Do not use the RJ45 port and 

terminal blocks 

at same time.  

Instead, plug the CAT5 cable into the RJ45 port.  

 

Use Terminal blocks: 

  Notice: 

If the audio input cable is supplied by the installation personnel, the cable 
must be shielded. 

DA has a balanced input connection. A balanced connection is recommended to 
reduce AC power interference, especially when using a long cable. For short cables 
that have an unbalanced connection, the signal impedance should be less than 600 
ohms. 

The following steps describe connecting a balanced input connection: 

1. 

Pull the input cable through the

 

terminal

 

protection

 

cover, as shown in Figure 1. 

 

Figure 1 Pulling the input cable through the terminal protection cover 

Содержание KB-DA4060

Страница 1: ...KB DA4060 High Efficiency Power Amplifier User Manual M_2000060690_EN_1 1 Easy Installation Easy Info Reading Easy Access Control Easy Maintenance...

Страница 2: ...contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Honeywell shall have no liability for any error or damage of any kin...

Страница 3: ...dled This sign means to alert the user of important operation and maintenance instructions Caution To avoid electrocution do not use polarized plug with an extension cord receptacle or other outlet un...

Страница 4: ......

Страница 5: ...gh too low or fluctuates too drastically it is recommended to install a stable AC power source The appliance is not waterproof Do not expose the appliance to rain or moisture and avoid splashing it wi...

Страница 6: ...lightning safety logos to prevent an electric shock When the power is turned on do not physically alter the appliance to avoid damaging the equipment Honeywell assumes no liability for appliance malfu...

Страница 7: ...Introduction 1 Audience 1 How to Use This Manual 2 1 Introduction 3 Features 3 Functions 3 Power Supply Protection 3 Overheating Protection 4 Overload and Short Circuit Protection 4 Fault Detection a...

Страница 8: ...iv Grounding Cable 9 Audio Input Cable 10 Output Cable 11 Completing Installation and Commissioning 12 Precautions 13 4 Technical Specifications 14 5 Packing List 15...

Страница 9: ...ures functions and applications Chapter 2 Package Contents Package content details of the KB DA4060 High Efficiency Power Amplifier Chapter 3 User Interface KB DA4060 High Efficiency Power Amplifier f...

Страница 10: ...using the KB DA4060 High Efficiency Power Amplifier and pay close attention to all warnings and instructions Keep this manual for later use and reference This manual has been reviewed to ensure its a...

Страница 11: ...CLASS D power amplifier with high efficiency and energy conservation Contains four independent channels The rated output power of each channel is 60W Each channel has 100V or 70V of output Supports b...

Страница 12: ...o high Overload and Short Circuit Protection When the DA power supply detects a circuit overload or if a short circuit occurs the DA automatically disconnects the power The DA remains protected and si...

Страница 13: ...ent In this case the light turns yellow 6 CLIP Peak clipping indicator light When the input signal exceeds the rated peak value the indicator light turns red 7 SIGNAL Signal indicator light This light...

Страница 14: ...ble 4 for port PIN descriptions 2 Cooling fan 3 Audio input and control ports FAULT A If a DA fault occurs it is protected or it is self tested ports A and B experience a short circuit B CH1 CH2 CH3 C...

Страница 15: ...output voltage is VCC 12V 24V the DA is being self tested When the DA has no input voltage the DA is working normally 9 Balanced positive input of CH4 10 Balanced negative input of CH4 11 DA fault inf...

Страница 16: ...installation of the DA prepare the following tools Anti static wrist strap Anti static gloves Cutting pliers Wire cutters Electrical cable crimping pliers Materials For the installation of the DA pre...

Страница 17: ...t are intact see Chapter 2 If an item is missing please contact the appropriate vendor Connecting the Cables These cables include the grounding cable main and backup power cables audio input cable and...

Страница 18: ...t Use Terminal blocks Notice If the audio input cable is supplied by the installation personnel the cable must be shielded DA has a balanced input connection A balanced connection is recommended to re...

Страница 19: ...2 Connecting the input cables to the input terminal 3 Connect the input terminals to their corresponding input ports as shown in Figure3 Figure 3 Connecting the input terminals Output Cable 1 Pull th...

Страница 20: ...ompleting Installation and Commissioning Once the DA hardware and cables are installed complete the following commissioning procedures 1 Set the audio volume to a minimum level 2 Press the DA front pa...

Страница 21: ...Cables section for more information Pay particular attention to which audio input source is selected and configure the output signal level appropriately as this can save electricity Do not connect the...

Страница 22: ...hm Signal to noise ratio 88dB with A Weight Non linear distortion 0 1 at 1 3 rated power 1kHz Indicator lights 1 power indicator light 4 signal lights 4 peak clipping lights 4 equipment protection lig...

Страница 23: ...15 5 Packing List Name Quantities KB DA4060 High Efficiency Power Amplifier 1 Audio input connector 2 Audio output connector 2 Safety shield 1 Screws 2 AC power cable 1 Product manual 1...

Страница 24: ......

Страница 25: ...Co Ltd No 257 Junye Road Guangzhou GETDD East 510530 China Phone 86 20 2839 9600 Fax 86 20 2839 8706 Website www empertech com Manual_KB D Series_EN1 0 Sep 2011 Subject to change without notice 2011 H...

Отзывы: