7
Table 3 RJ45 Port
PIN
Description
Figure
1
Balanced positive input of
CH2
2
Balanced negative input of
CH2
3
DA fault information output
When the DA is working properly, the
output voltage is
VCC (12V-24V).
When the DA faults, is protected, or undergoes self-
testing, the output voltage is GND (0V).
4
Balanced positive input of
CH1
5
Balanced negative input of
CH1
6
GND (0V)
7
VCC (12V-24V,
powered by an external device
)
8
Self-test port
When the DA output voltage is VCC (12V-24V), the DA is
being self-tested.
When the DA has no input voltage, the DA is working
normally.
9
Balanced positive input of
CH4
10
Balanced negative input of
CH4
11
DA fault information output
When the DA is working properly, the
output voltage is
VCC (12V-24V).
When the DA faults, is protected, or undergoes self-
testing, the output voltage is GND (0V).
12
Balanced positive input of
CH3
13
Balanced negative input of
CH3
14
GND (0V)
15
VCC (12V-24V,
powered by an external device
)
16
Self-test port
When the DA output voltage is VCC (12V-24V), the DA is
being self-tested.
When the DA has no input voltage, the DA is working
normally.