Gas Connection and check
D: End of fitting with 1/2 BSP male thread(See Figure 17)
Figure 17
The cooktop valve is in the closed state, open the air supply valve, coated the connector with moderate
amounts of soapy water, if there is air bubbles that it means there is leakage, tighten the connector and
test again. If repeat 3 to 4 times and there is still air bubbles, notify professionals to deal with it.
Cut Out dimensions
The dimensions of the cut-out are given in the diagram. (Dimensions are given in inch.)
Figure 18
Figure 19
Electrical connections
Any electrical work required to install this gas cooktop should be carried out by a qualified electrician or
competent person.
Check the last letter of your model to know the electrical supply type: A is for AC,D is for DC.
See PAGE 1 to check the electrical supply of your model
The GAS COOKTOP MUST BE EARTHED
If the cooktops to be connected to a 120V, 60 Hz AC electrical supply.
Before switching on, make sure the electricity supply voltage is the same as that indicated on the
cooktops rating label.
Ensure that the cooktops supply cable does not come into contact with surfaces with temperatures
higher than 50 deg. C.
Figure 21
For model:24GC28
D
16
For model:30GC20 30GC21
30GC26
For model: 36GC22 36GC23
36GC24 36GC25
Figure 20
For model:36GC27