background image

Page 13

XPA HC-1

 Configuration and Operation

 Line Voltage

The XPA HC-1 can operate from any line voltage between 100 VAC and 250 VAC and from any line 

frequency between 50 Hz and 60 Hz. The amplifier will automatically detect which line voltage it 

is connected to and configure itself accordingly.

 AC Power Switch (rear panel)

The rear-panel AC Power switch controls the main AC power for your XPA HC-1. When this switch 

is in the Off position, the amplifier will not operate. Turning it On will put the XPA HC-1 into 

Standby mode. 

 AC Circuit Breaker (rear panel)

If an electrical power fault occurs, the button on the rear-panel Circuit Breaker will pop up. When 

the Circuit Breaker button is up, the XPA HC-1 will not operate, and neither the Status LED nor the 

Standby Button will be lit. The Circuit Breaker is reset by pressing the button firmly in.  

 Standby Switch (front panel push button)

Press to switch the amplifier On; press again to return to Standby; the halo ring around the button 

illuminates amber for Standby and blue for On. 

 Un-Balanced / Balanced Selector Switches

This switch selects between the Unbalanced (RCA) and Balanced (XLR) inputs.  Only one input 

will be active at once. (Both a balanced and an unbalanced source may be connected at the same 

time, and the switch used to select between them, but only one will be active at a time.)

 Status LED Switch

Disables the front panel Status LED when set to Off.

 Trigger Input and Output

When a trigger cable is connected to the Trigger Input (on the rear panel), and a trigger signal 

is received (between 5-20 V - AC or DC), the XPA HC-1 will switch from Standby to On; when the 

trigger signal ceases, the XPA HC-1 will return to Off. 
The trigger is typically connected to the preamp or pre/pro that provides a signal source for the 

XPA HC-1, and set to turn the XPA HC-1 on when the preamp or pre/pro is turned on. For multiple 

XPA HC-1 monoblocks, the Trigger Input of each amp may be connected to the Trigger Output of 

the previous unit.  
Whenever the XPA HC-1 is On, the Trigger Output will assert a 12 VDC signal, which may be used 

to turn on other trigger-enabled equipment. 

Содержание XPA HC-1

Страница 1: ...XPA HC 1 High Current Monoblock Power Amplifier COVER PICTURE HERE...

Страница 2: ......

Страница 3: ...ALL SERVICE TO QUALIFIED SERVICE PERSONNEL Do not install the XPA HC 1 amplifier near or above any heat sources such as radiators heating vents or other apparatus that produce heat Do not block any v...

Страница 4: ...HC 1 amplifier by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 The unit h...

Страница 5: ...roduction 3 About This Manual 4 Features 5 Unpacking 6 XPA HC 1 Front Panel 7 XPA HC 1 Rear Panel 9 Quick Start 11 Connections 12 Configuration and Operation 13 Care and Maintenance 14 Specifications...

Страница 6: ...Page 2 XPA HC 1...

Страница 7: ...ls later when there s room in your budget The XPA HC 1 High Current Monoblock Power Amplifier uses the same exceptional sounding short signal path Class A B output circuitry efficient Optimized Class...

Страница 8: ...as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful suggestions If you re really in a hurry to get started please read the Quic...

Страница 9: ...al linear power supply while improving efficiency and reliability and reducing overall weight Top quality parts and construction throughout promise years of reliable service Totally stable designed fo...

Страница 10: ...other issues when you unpack it please contact Emotiva immediately Gently remove your XPA HC 1 from the packing carton and remove all wrappings and shipping material It is important to save the box a...

Страница 11: ...Note The Status LED illuminates red during startup blue in normal operation and flashes red to indicate a fault 2 Standby Button Press to switch the amplifier On press again to return to Standby the...

Страница 12: ...Page 8 XPA HC 1...

Страница 13: ...from the Trigger Output to control other devices 3 Un Balanced Balanced Input Select Switch A high quality metal toggle switch selects between the Unbalanced RCA and Balanced XLR input Up selects the...

Страница 14: ...by pressing the button firmly in If the Circuit Breaker trips a second time please contact Emotiva or your nearest authorized Emotiva service representative 7 IEC Power Cord Receptacle The XPA HC 1 ca...

Страница 15: ...C 1 monoblocks to a signal source Set the Input Selector switch on each of your XPA HC 1 monoblocks for the type of input you re using unbalanced or balanced Connect each XPA HC 1 to a speakers 4 ohm...

Страница 16: ...p your speakers make sure to remove the jumpers on the input panel of each speaker Failure to remove these will damage your amplifier Connecting an input source to your XPA HC 1 Your XPA HC 1 monobloc...

Страница 17: ...halo ring around the button illuminates amber for Standby and blue for On Un Balanced Balanced Selector Switches This switch selects between the Unbalanced RCA and Balanced XLR inputs Only one input w...

Страница 18: ...ould be cleaned gently with a soft rag If something sticky gets on the front panel or case of the XPA HC 1 it should be cleaned with a mild cleaning solution applied to a soft rag followed by wiping w...

Страница 19: ...t Output Power 300 watts RMS 20 Hz 20 kHz THD 0 1 into 8 Ohms 600 watts RMS 20 Hz 20 kHz THD 0 2 into 4 Ohms Power Bandwidth at rated power 8 Ohm load 20 Hz to 20 kHz 0 1 dB Broad Band Frequency Respo...

Страница 20: ...on halo ring changes color to indicate Standby or On Status LED blue changes to red to indicate a fault condition Rear Panel Controls AC Power switch rocker switch switches AC main power Status LEDs s...

Страница 21: ...boxed without feet and connectors 24 3 4 wide x 12 high x 14 1 2 deep boxed Weight Boxed 28 lbs Unboxed 21 5 lbs Mounting Clearance Adequate clearance for cooling must be allowed above each XPA HC 1 m...

Страница 22: ...ut the front panel Status LED is not lit Reason The front panel status LED is turned off Set the Status LEDs switch on the rear panel to On Problem No sound or distorted sound is heard the Standby but...

Страница 23: ...thin the Term of the Warranty A claim shall not be valid and Emotiva has no obligation related to the claim if it is not made within the Term and if it is not made in strict compliance with the requir...

Страница 24: ...controls by user EMOTIVA SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM OR RELATED TO ANY DEFECTS IN OR DAMAGES TO ITS PRODUCTS SOME STATES DO NOT ALLOW THE EXCLUSION OR...

Страница 25: ...you do not have the original Emotiva Audio packaging please check with our sales department to purchase replacement shipping cartons How does the Warranty and service apply to international orders The...

Страница 26: ...te to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of our products wit...

Страница 27: ......

Страница 28: ......

Отзывы: