Page 10
Stealth PA-1
Stealth PA-1 Rear Panel
1. AC Power Switch
Switches the main AC power to the Stealth PA-1 On and Off. When this switch is Off, the PA-1 will
not operate; when this switch is On, the PA-1 will either be continuously on, or will turn on when it
senses an input signal, depending on the position of the Auto/On Switch.
2. AC Power Fuse
The Stealth PA-1 is protected by a 20 mm 3.15A Time Delay (Slo-Blo) fuse. If the fuse blows, replace
it with a new fuse of the same value; be sure to use a time delay type fuse. The same fuse value is
used for both 115 VAC and 230 VAC operation.
To change the fuse, turn off the main AC power, and remove the AC power cord from the PA-1.
The fuse holder slides towards you out of the PA-1 like a drawer. To release the fuse holder, reach
across the opening in the power cord receptacle with a small bladed screwdriver and pry the
small tab on that side of the fuse holder cover straight out towards you. Replace the fuse and then
replace the fuse holder; pressing it firmly in until it snaps into place.
3. IEC Power Cable Receptacle
The Stealth PA-1 uses a standard IEC power cable. A good quality commercial power cable is
provided, but you can substitute any power cable that fits a standard IEC receptacle.
The Stealth PA-1 will operate on any AC line voltage between 100 VAC and 264 VAC.