Important Safety Precautions and Explanation of Symbols

!

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 

important installation, operation, and service instructions in this manual.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the 

presence of uninsulated dangerous voltages within the enclosure that may be of sufficient magnitude to 

constitute a risk of electrical shock to the user. 
Please read this manual thoroughly before attempting to install, configure, or operate the XPA-5 power 

amplifier. After successful installation and configuration of the XPA-5, be sure to retain this manual in a safe 

place for future reference. 
Safety is a key component to a long lasting and trouble free installation. Please read and follow all 

instructions and heed all warnings on the XPA-5 and in this manual. The vast majority of the subsequent 

safety precautions are common sense. If you are not comfortable with the installation of audio/video 

entertainment equipment, you should seek the services of a qualified installation professional or call us for 

help.

WARNING: To REDUCE ThE RIsk of fIRE oR ElECTRIC shoCk, Do NoT UsE ThE  

XPA-5 NEAR WATER oR IN WET loCATIoNs, Do NoT EXPosE IT To RAIN oR moIsTURE, Do NoT 

EXPosE IT To DRIPPING oR sPlAshING fRom oThER soURCEs, AND ENsURE ThAT No oBJECTs 

fIllED WITh lIQUIDs (sUCh As VAsEs) ARE PlACED oN IT. DoING so mAy REsUlT IN DAmAGE To 

ThE UNIT AND ThE RIsk of ElECTRIC shoCk, WhICh mAy REsUlT IN BoDIly INJURy oR DEATh.
WARNING: To REDUCE ThE RIsk of ElECTRIC shoCk, Do NoT REmoVE ThE CoVER fRom ThE XPA-

5. ThERE ARE No UsER-sERVICEABlE PARTs INsIDE ThE UNIT. REfER All sERVICE To QUAlIfIED 

sERVICE PERsoNNEl.

Do not install the XPA-5 near or above any heat sources such as radiators, heating vents, or other apparatus’ 

that produce heat. Do not block any ventilation openings or heat sinks. Avoid installing the unit directly 

above other heat-producing equipment unless sufficient ventilation or forced-air cooling is provided.
Do not install the XPA-5 in locations without proper ventilation. The XPA-5 should not be operated on a bed, 

sofa, rug, or similar surface that may block vents. The unit should not be installed in an enclosed location 

such as a bookcase, cabinet, or closed equipment rack unless sufficient forced-air ventilation is provided.
Always install your XPA-5 according to the manufacturer’s instructions and only use attachments or 

accessories specified by the manufacturer.
Do not install the XPA-5 on any stand, shelf, or other piece of furniture that is unable to support its weight. If 

a cart is used to move the unit, use caution to avoid injury from tip-over.
Connect the XPA-5 only to power sources of the correct voltage (as shown in this manual and on the XPA-5 

unit). 
Protect power supply cables from being pinched, walked on, or otherwise damaged. Be especially careful 

where the power cable enters the power outlet and the unit. 
Only connect the XPA-5 to an electrical outlet or extension cord of appropriate type and rating. 
DO NOT defeat the safety purpose of a grounding or polarized plug by removing ground pins or using 

unsafe adapters. A polarized plug has two blades - one wider than the other. A grounding plug has a 

third ground prong in addition to the two main conductors. The wide blade or third groundling prong is 

provided for your safety. If the provided plug does not fit your outlet, consult an electrician to replace your 

obsolete outlet. If you replace the power cord, only use one of similar type and equal or greater current 

rating.
The power cable for the XPA-5 should be unplugged from the outlet during severe electrical storms, or 

when unused for a long period of time.

!

Содержание Gen 2 XPA-5

Страница 1: ......

Страница 2: ......

Страница 3: ...5 near or above any heat sources such as radiators heating vents or other apparatus that produce heat Do not block any ventilation openings or heat sinks Avoid installing the unit directly above other...

Страница 4: ...The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 The unit has been exposed to rain 4 The unit exhibits a marked change in performance 5 T...

Страница 5: ...is Manual 4 Features 5 Unpacking 6 XPA 5 Front Panel 7 XPA 5 Rear Panel 8 XPA 5 Inputs Rear Panel 10 Quick Start 11 Connections 12 Configuration and Operation 13 Care and Maintenance 14 Specifications...

Страница 6: ...Page 2 XPA 5...

Страница 7: ...signed power supply and output stages high quality parts and construction throughout incredibly good sound quality and exceptional value To that we ve added some improvements including solid machined...

Страница 8: ...d direct as possible Even if you re an expert user you will probably find some interesting information and useful suggestions If you re really in a hurry to get started please read the Quick Start sec...

Страница 9: ...ew styling an updated more evolved version of our classic XPA amplifier style Front panel status LEDs display XPA 5 status and indicate fault conditions Stealth mode lets you disable the status LEDs f...

Страница 10: ...u unpack it please contact Emotiva immediately Gently remove your XPA 5 from the packing carton and remove all wrappings and shipping material It is important to save the box and all packing materials...

Страница 11: ...te The Status LEDs can be disabled by the Status Indicator switch on the rear panel 2 Standby Button Press to switch the amplifier On press again to return to Standby the halo ring around the button a...

Страница 12: ...h Disables the front panel status LEDs when set to Off 3 Inputs Balanced and unbalanced inputs and Input Selector switches See the Inputs Rear Panel section for details 4 AC Power Switch Switches the...

Страница 13: ...ld plated audiophile quality five way binding posts with clear shields accept banana plugs lugs or bare wire 7 IEC Power Cord Receptacle Accepts a standard removable IEC AC power cable a high quality...

Страница 14: ...2 Balanced XLR Input Standard XLR connector accepts a line level balanced input 3 Un Balanced Balanced Selector Switch High quality metal toggle switches independently selects between the Unbalanced R...

Страница 15: ...cure location for your XPA 5 Connect your XPA 5 to a signal source Connect your XPA 5 to a set of speakers 4 ohm or 8 ohm using reasonably heavy gauge speaker wires at least 18 gauge Find some music y...

Страница 16: ...pre made speaker cables at reasonable prices You will find them in the Interconnects section of our website at www emotiva com Connecting an input source to your XPA 5 Your XPA 5 amplifier has both ba...

Страница 17: ...itches Independently switch between the Unbalanced RCA and Balanced XLR inputs Up selects the Unbalanced input and Down selects the Balanced input Only one input can be used at once for each input It...

Страница 18: ...d be cleaned gently with a soft rag If something sticky gets on the front panel or case of the XPA 5 it should be cleaned with a mild cleaning solution applied to a soft rag followed by wiping with a...

Страница 19: ...t rated power 8 Ohm load 20 Hz to 20 kHz 0 075 dB Minimum Recommended Load Impedance 4 Ohms which equals one 4 Ohm load or two paralleled 8 Ohm loads Frequency Response 10 Hz to 80 kHz 0 1 5 dB THD no...

Страница 20: ...nd switched Front Panel Controls and Indicators Standby push button halo ring changes color to indicate Standby or On Status LEDs one per channel blue Status LEDs change to red to indicate a fault con...

Страница 21: ...Page 17 XPA 5 Dimensions 17 wide x 7 75 high x 19 deep unboxed includes feet and binding posts 23 1 2 wide x 12 high x 24 3 4 deep boxed Weight 70 4 pounds unboxed 81 5 pounds boxed...

Страница 22: ...heard the Standby button halo is lit blue the status LEDs are lit blue Reason The XPA 5 is not indicating a fault condition Check your source Check your Balanced Unbalanced Selector Switches Check you...

Страница 23: ...ll Emotiva do Emotiva will at its option either i repair the product or ii replace the product with a new consumer product which is identical or reasonably equivalent to the product Emotiva may provid...

Страница 24: ...with a returned material authorization number RMA 3 Ship the product to Emotiva at the following address with the RMA written in large bold numbers on the outside of the box and with the letters RMA w...

Страница 25: ...ty and maximum reliability from your XPA 5 amplifier and the speakers connected to it Emotiva Audio offers high quality speaker cables and audio interconnects that feature solid engineering premium bu...

Страница 26: ...rate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of our products w...