background image

Page 13

Fusion Flex Amplifier

Configuration

Operating Voltage

Verify that the EFusion Flex Amplifier is configured for the correct operating voltage for your area. 

(Voltage is set via the AC Input switch on the rear panel of the Fusion Flex Amp).

Power Mode

The way in which the Fusion FLex Amplifier responds to the Trigger Input, audio signals, and the 

front panel Standby switch is determined by the setting of the Power Mode switch (the small bat 

switch on the rear panel below the speaker outputs, to the right of the Trigger and IR Inputs). 

When the rear panel Power rocker switch is set to Off, the Fusion Flex Amp is 

powered completely 

off 

and will not respond to any other control, switch setting, or input. In order for the Fusion Flex 

Amp to operate as described below, the rear panel Power rocker switch must be set to On.

• 

When the Power Mode switch is set to On, the Fusion Flex Amp is controlled by the front 

panel Standby switch, which toggles between Standby and operating (On) modes each time 

it is pressed.

• 

When the Power Mode switch is set to Auto, the Fusion Flex Amp is controlled by audio input; 

the Fusion Flex Amp switches On when there is audio signal present at any of the inputs (this 

will occur even when audio arrives at an input which is not assigned as a source); the Fusion 

Flex Amp will return to Standby mode about fifteen minutes after audio input signal is no 

longer present.

• 

When the Power Mode is set to Off, the Fusion Flex Amp will switch On when a trigger signal 

is received,  and will return to Standby mode when the trigger signal is no longer present.

Remote Control

The Fusion Flex Amp responds to certain remote control commands (including the Power On 

command) when in Standby mode. The rear panel Power rocker switch is a manual, mechanical 

switch; when it is set to Off, the Fusion Flex Amp is 

powered completely off 

and will not respond 

to any remote control commands. The remote control Power Off commands (and the Standby 

button) return the Fusion Flex Amp to Standby, but do not remove all AC mains power (the 

remote control receivers remain powered on).

Содержание Fusion Flex

Страница 1: ......

Страница 2: ......

Страница 3: ...vice personnel Do not install the Fusion Flex Amplifier near or above any heat sources such as radiators heating vents or other apparatus that produce heat Do not block any ventilation openings or hea...

Страница 4: ...r Fusion Flex Amplifier by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 Th...

Страница 5: ...fier Front Panel 7 Fusion Flex Amplifier Remote Control 8 Fusion Flex Amplifier Rear Panel 9 Inputs and Outputs 11 Installation Tips 12 Configuration 13 Operation 14 Care and Maintenance 16 Performanc...

Страница 6: ...Page 2 Fusion Flex Amplifier...

Страница 7: ...or using the standard trigger input or it can be set to switch on automatically when it senses an audio signal The digitally controlled analog volume control offers precise control near perfect channe...

Страница 8: ...ifier We suggest that you read through the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful sug...

Страница 9: ...y controlled analog volume control for precisely repeatable control and superb channel tracking Two stereo inputs with manual or automatic input switching Manual triggered or automatic power switching...

Страница 10: ...Gently remove your Fusion Flex Amplifier from the packing carton and remove all wrappings and shipping material It is important to save the box and all packing materials in case your power amp ever ne...

Страница 11: ...essing Auto instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has priority When each input mode is selected the corresponding LED wil...

Страница 12: ...Button Pressing 1 or 2 manually selects that input pressing the Auto Button instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has pr...

Страница 13: ...s accept bare wires spade lugs and banana plugs 5 Power Switch Switches the AC mains power to the Fusion Flex Amplifier On and Off When this switch is Off the Fusion Flex Amplifier will not respond to...

Страница 14: ...r between On and Standby 9 IR Input Connect an external IR sensor to this input if the Fusion Flex Amplifier is mounted such that IR remote control signals cannot reach the front panel directly 10 Pow...

Страница 15: ...to Trigger Input RS 232 serial input output on rear panel 9 pin d connector female Front panel controls and indicators Standby large push button toggles Standby mode Standby LED 1 red for Standby mod...

Страница 16: ...ngaged by pressing the front panel Input 1 button and holding it for approximately 3 seconds THIS LOCKOUT MODE WILL REMAIN IN EFFECT EVEN IF THE FUSION FLEX AMP IS SET INTO STANDBY MODE OR POWERED OFF...

Страница 17: ...toggles between Standby and operating On modes each time it is pressed When the Power Mode switch is set to Auto the Fusion Flex Amp is controlled by audio input the Fusion Flex Amp switches On when...

Страница 18: ...t after a short delay if the Power Mode switch is in Auto mode the Standby button on the IR remote is pressed or the code is received from a compatible control the Power Off command is received from a...

Страница 19: ...button is pressed and move smoothly up or down if the appropriate button is held down When under the control of an RS 232 serial controller the level may be either moved up or down or set to an expli...

Страница 20: ...sion Flex Amp should be cleaned gently with a soft rag If something sticky gets on the front panel or case of the Fusion Flex Amp it should be cleaned with a mild cleaning solution applied to a soft r...

Страница 21: ...dB A weighted Frequency response 20 Hz to 20 kHz 0 08 dB Trigger and control Trigger Input 5 20 VAC or VDC Serial Standard RS 232 drive levels Protection The Fusion Flex Amplifier is protected against...

Страница 22: ...is heard from one or both channels the Status LED is lit blue Reason The Fusion Flex Amp is On and is not indicating a fault Verify that the correct input is selected Verify that the Volume is not al...

Страница 23: ...What will Emotiva do Emotiva will at its option either i repair the product or ii replace the product with a new consumer product which is identical or reasonably equivalent to the product Emotiva ma...

Страница 24: ...ide you with a returned material authorization number RMA 3 Ship the product to Emotiva at the following address with the RMA written in large bold numbers on the outside of the box and with the lette...

Страница 25: ...anual is accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of o...

Страница 26: ...Emotiva Audio Corporation 135 Southeast Parkway Court Franklin TN 37064 emotiva com...

Отзывы: