background image

3

The installation may be done by the professional heating technician only and in the accordance with the 

connection plan. Moreover, the installation must comply the currently valid VDE regulations and must 

comply as well as the specifications issued by your energy supplier.

The installation must always be done when the electricity supply is switched off. All the safety speci-

fications must be observed.

Observe the maximum switching current stated in the technical specifications!

Our company is not liable for the unprofessional installation.

Technical Specifications 

Operating Voltage: 230 V AC 50 Hz, 400 V AC 50 Hz

Contact: 1 two-way contact

Switching Current: 16 (4) A – 230 V, 6 (1) A – 400 V

Temperature Controlling Range: 0 °C – 90 °C

Sensor Unit: liquid sensor

Coverage: IP40

Do not dispose with domestic waste. Use special collection points for sorted waste. Contact 

local authorities for information about collection points. If the electronic devices would be disposed 

on landfill, dangerous substances may reach groundwater and subsequently food chain, where 

it could affect human health.

CZ | Příložný termostat 

Vlastnosti

•  Příložný termostat s vnější stupnicí montovaný na povrch potrubí.

•  Jednoduché připevnění pomocí napínací pružiny.

•  Teplotní rozsah 0 °C – 90 °C (rozlišení 5 °C).

•  Jednoduché elektrické připojení pomocí dostatečně velkých kabelových svorek.

Montáž 

1.  Přiložte termostat na povrch potrubí pevně proti trubce topení a zajistěte ho přiloženou napínací 

pružinou tak, aby termostat přímo dosedal na trubku. (Jakákoli izolace se musí odstranit na místě 

instalace před upevněním čidla.)

2.  Nadbytečnou část pružiny lze odstřihnout.

Elektrické připojení

 

L Output  L Output  L Input

1.  Otevřete termostat tím, že odstraníte povytažením číselník (1) a uvolníte velký plastový šroub (2). 

2.  Odstraňte víko pouzdra. Čtyři kabelové svorky, které nyní můžete vidět, se připojí takto: 

•  Svorka C a 1 = otvírač 

3.  Termostat se otevře při rostoucí teplotě a uzavře v případě klesající teploty (např. funkce = „topení“).

•  Svorka C a 2 = otvírač 

Содержание P5681

Страница 1: ...ylgowy HU rintkez s termoszt t SI Nale ni termostat RS HR BA ME Termostat s obujmicom DE Anlegethermostat UA RO MD Termostat de contact LT Pridedamas termostatas LV Piestiprin mais termostats EE Pindp...

Страница 2: ...d from the spot where the sensor is going to be mounted 2 The redundant part of the spring may be cut off Electric Connection L Output L Output L Input 1 Open the thermostat by pulling out the dial 1...

Страница 3: ...orities for information about collection points If the electronic devices would be disposed on landfill dangerous substances may reach groundwater and subsequently food chain where it could affect hum...

Страница 4: ...informace o sb rn ch m stech kontaktujte m stn ady Pokud jsou elektrick spot ebi e ulo en na skl dk ch odpadk nebezpe n l tky mohou prosakovat do podzemn vody a dostat se do potravn ho et zce a po ko...

Страница 5: ...n ma Krytie IP40 Nevyhadzujte elektrick spotrebi e ako netrieden komun lny odpad pou ite zbern miesta trieden ho odpadu Pre aktu lne inform cie o zbern ch miestach kontaktujte miestne rady Pokia s ele...

Страница 6: ...Hz 400 V AC 50 Hz Styki 1 styk podw jny Pr d prze czany 16 4 A 230 V 6 1 A 400 V Zakres sterowanej temperatury 0 C 90 C Czujnik czujnik cieczowy Stopie ochrony IP40 Zgodnie z przepisami Ustawy o ZSEi...

Страница 7: ...e kell tartani Vegye figyelembe a m szaki el r sokban felt ntetett maxim lis kapcsol si ramot C g nk nem v llal felel ss get a szakszer tlen telep t s rt M szaki le r s zemi fesz lts g 230 V AC 50 Hz...

Страница 8: ...je Sponka ozemljitev Instalacijo sme opravljati le profesionalni in talater v skladu z na rtom priklju itve Poleg tega mora instalacija ustrezati tudi aktualno veljavnim direktivam VDE in specifikacij...

Страница 9: ...kcija grijanja Stezaljka C i 2 otvara 4 Termostat se zatvori prilikom temperature u porastu i otvori u slu aju da temperatura pada npr funkcija hla enja Stezaljka uzemljenje Instalaciju mo e vr iti sa...

Страница 10: ...e t sich bei sinkender Temperatur z B Funktion Heizung Klemme C und 2 ffner 4 Der Thermostat schlie t sich bei steigender Temperatur und ffnet sich bei sinkender Temperatur z B Funktion K hlung Klemme...

Страница 11: ...ins Grundwasser einsickern und in den Lebensmittelumlauf gelangen Ihre Gesundheit besch digen und Ihre Gem tlichkeit verderben UA 0 C 90 C 5 1 2 L Output L Output L Input 1 1 2 2 C a 1 3 C a 2 4 VDE 2...

Страница 12: ...e le pute i vedea acum se conecteaz astfel Borna C i 1 deschiz tor 3 Termostatul se deschide la temperatura n cre tere i se nchide la temperatura n descre tere de ex func ia nc lzire Borna C i 2 desch...

Страница 13: ...r bus montuojamas jutiklis b tina pa alinti bet koki izoliacij 2 Likusi nereikaling spyruokl s dal galima nukirpti Elektros jungtis L Output L Output L Input 1 Patraukite disk 1 ir atidarykite termost...

Страница 14: ...ot nostiep anas atsperi Temperat ras diapazons no 0 C 90 C pielaide 5 C Vienk r a piesl g ana elektr bai izmantojot pietiekami liel s kabe u skavas Uzst d ana 1 Stingri pievienojiet termostatu radiato...

Страница 15: ...et jo pa vald bu Ja elektronisk s ier ces tiek likvid tas izg ztuv b stamas vielas var non kt pazemes de os un t l k ar bar bas d kur t s var ietekm t cilv ka vesel bu EE Pindpaigaldusega termostaat K...

Страница 16: ...s toodud maksimaalset l litusvoolu Meie ettev te ei vastuta mitteprofessionaalse paigalduse eest Tehnilised andmed Talitluspinge 230 V vahelduvvoolu 50 Hz 400 V vahelduvvoolu 50 Hz hendus 1 kahesuunal...

Страница 17: ...e de temp rature de 0 C 90 C r solution 5 C Connexion lectrique simple l aide de bornes suffisamment grandes Installation 1 Placez le thermostat fermement contre la surface du tuyau de chauffage et fi...

Страница 18: ...t doivent tre respect es Respecter le courant de commutation maximal sp cifi dans les caract ristiques techniques Nous ne sommes pas responsables en cas d installation incorrecte Donn es techniques Te...

Страница 19: ...a L installazione pu essere eseguita solo da un idraulico professionista in conformit con il piano di connessione Inoltre l impianto deve anche essere conforme alle linee guida VDE attualmente applica...

Страница 20: ...ctan de la siguiente manera Pinza C y 1 abridor 3 El termostato se abre cuando la temperatura aumenta y se cierra cuando la temperatura disminuye por ejemplo funci n calefacci n Pinza C y 2 abridor 4...

Страница 21: ...er kan worden afgesneden Elektrische aansluiting L Output L Output L Input 1 Open de thermostaat door de cijferplaat draaiwiel 1 even naar buiten te trekken en de grote plastic schroef 2 los te draaie...

Страница 22: ...inzamelpunten voor gesorteerd afval Neem contact op met de lokale autoriteiten voor informatie over inzamelpunten Als de elektronische apparaten zouden worden weggegooid op stortplaatsen kunnen gevaar...

Страница 23: ...23...

Страница 24: ...em obmo ju Republike Slovenije 9 Proizvajalec zagotavlja proti pla ilu popravilo vzdr evanje blaga nadomestne dele in priklopne aparate tri leta po poteku garancijskega roka 10 Naravna obraba aparata...

Отзывы: