7
Wiring Diagram
Voltage connection diagram for connecting thermostat P5603R to a boiler
with an „NO“ contact:
Max 230 V 6(2) A
230 V~
N
N
L
L
NO
NC
COM
Heating device requiring
230 V power supply, e.g.
central heating pump.
Thermostat
* When connecting a cooling device to the thermostat, connect the „L“
phase conductor to the „NC“ terminal.
Zero-voltage connection diagram for connecting thermostat P5603R to
a boiler with an „NO“ contact:
Max 230 V 6(2) A
NO
COM
NO
NC
COM
Heating device requiring
zero-voltage contact, e.g.
gas boiler.
Thermostat
Putting the Device into Operation
1. Remove the back portion of the thermostat and insert 2× 1.5 V AA
batteries. Only use 1.5 V alkaline batteries; do not use rechargeable
1.2 V batteries.
2. Replace the back of the thermostat.