18
TROUBLESHOOTING
Problem / Symptom
Solution
Strange or no measurement of Rain Sensor
1. Check the drain hole in the rain collector.
2. Check the balance indicator
.
Strange or no measurement of Thermo / Hygro
Sensor
1. Check the radiation shield.
2. Check the sensor casing
.
Strange or no measurement of Wind Speed and
Direction
1. Check wind cups (Anemometer).
2. Check the wind vane.
and
(Signal lost for 15 minutes)
1. Relocate the main unit and 5-in-1 sensor
closer to each other.
2. Make sure the main unit is placed away from
other electronic appliances that may interfere
with the wireless communication (TVs,
computers, microwaves).
3. If problem continues, reset both main unit and
5-in-1 sensor.
and
(Signal lost for 1 hour)
SPECIFICATIONS
CONSOLE
Dimensions (W x H xD)
202 x 138 x 38mm
Weight
530g with backup batteries
Main power
DC 5V, 600mA adaptor
Backup battery
3 x AAA size 1.5V batteries (Alkaline batteries recommended)
Support sensor
Wireless 5-in-1 sensor (Wind speed, Wind direction, Rain gauge, thermo-hygro)
RF frequency
868Mhz
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS / Weekday
Hour format
12hr AM / PM or 24hr
Calendar
DD/MM
Weekday in 5 languages
EN, FR, DE, ES, IT
Time signal
DCF
DST
AUTO / OFF
INDOOR BAROMETER
Barometer unit
hPa, inHg and mmHg
Measuring range
540 ~ 1100hPa
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ± 0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution
1hPa / 0.01inHg / 0.1mmHg
Weather forecast
Sunny/Clear, Slightly Cloudy, Cloudy, Rainy, Rainy/Stormy and Snowy
Memory modes
Max & Min from last memory reset (with time stamp), Historical data of past 24 hours
Alarm
Pressure change alarm
INDOOR TEMPERATURE
Temperature unit
°C or °F
Operating range
-5°C to 50°C (14°F to 122°F)
Resolution
1 decimal place
Accuracy
+/- 1°C or 2°F typical @ 25°C (77°F)
Memory modes
Max & Min from last memory reset (with time stamp), Historical data for last 24hrs
Alarm
Hi / Lo Temperature Alert