background image

 

 

4 / 16 

LRT Home Es 11/22kW operating instructions 

1

 

About this document 

Read the operating instructions before using the charging station. This is a prerequisite for trouble-free use. 

Observe the safety instructions and warnings in this documentation. 

Keep the documentation accessible to all users. 

This documentation is a permanent part of the described product and must be handed over to the buyer at the time 
of sale. 

Scope 

The operating instructions apply to the models: 

 

LRT Home Es 11kW 

 

LRT Home Es 22kW 

Target group 

The operating instructions are intended for: 

 

The operator company of the charging station 

 

The users of the charging station 

Qualification of electricians 

Installation, maintenance and repair work on the charging station may only be carried out by qualified electricians. 
They must be trained in the use of a mains connection. 

Due to their technical training, knowledge and experience as well as knowledge of the relevant standards and 
regulations, electricians are able to carry out work on electrical systems and to recognise possible dangers 
independently. 

In Germany, qualified electricians must comply with the provisions of the accident prevention regulation German 
Social Accident Insurance (DGUV) Regulation 3 (e.g. master electrician). In other countries, corresponding regulations 
apply and must be observed. 

Содержание LRT Home Essential Plus 11

Страница 1: ...Operating instructions LRT Home Essential Plus 11 LRT Home Essential Plus 22 ...

Страница 2: ...E Mail anfrage lrt de Germany URL www lrt emobility de All rights to this document are owned by LRT Automotive GmbH LRT Automotive GmbH reserves the right to make changes or improvements to its products without notice Reproduction excerpt or reference without prior written consent is prohibited 2021 Version Date of issue Amendments 1 0 07 05 2021 First edition ...

Страница 3: ...use 6 2 2 Foreseeable misuse 6 2 3 Safety instructions 7 2 4 Warranty and disclaimer 8 3 Description 8 3 1 Structure 8 3 2 Function 9 3 3 Technical data 9 4 Installation 10 5 Operation 11 6 Maintenance Cleaning 12 6 1 Testing the safety function 12 6 2 Cleaning 12 7 Disposal 12 8 CE Declaration of Conformity 13 ...

Страница 4: ...ntended for The operator company of the charging station The users of the charging station Qualification of electricians Installation maintenance and repair work on the charging station may only be carried out by qualified electricians They must be trained in the use of a mains connection Due to their technical training knowledge and experience as well as knowledge of the relevant standards and re...

Страница 5: ...imminently dangerous situation which if not avoided could result in serious injury or death CAUTION This signal word is used to indicate an imminently dangerous situation which if not avoided could result in minor or moderate injury ATTENTION This signal word without a warning sign is used to indicate a possible danger of property damage NOTE This signal word indicates additional information that ...

Страница 6: ...harging with alternating current AC has been designed and manufactured according to the international standard IEC 61851 meets the requirements of protection class IP44 is suitable for outdoor use is intended for use in private areas e g private properties is intended exclusively for stationary installation NOTE Do not use extension cables cable drums multiple sockets or adapters to operate the ch...

Страница 7: ... in progress Only use the charging station after it has been commissioned by a qualified electrician DANGER Warning of electromagnetic interference radiation Charging stations from LRT Automotive GmbH which are operated as intended comply with the European directive on electromagnetic compatibility with regard to interference radiation In the event that persons with pacemakers or defibrillators wi...

Страница 8: ...perating instructions Improper handling and improper use of the charging station Unauthorised and improper installation maintenance and repair of the charging station Modifications or changes to the charging station Damage caused by fire flood and other natural disasters Transport damage or damage caused during installation 3 Description 3 1 Structure 1 Charger housing 4 Charging cable with coupli...

Страница 9: ...3 Technical data General data Model Home Essential Plus 11 Home Essential Plus 22 Part number AC09C AC10C Housing dimensions LxWxH 48x36x13 cm Housing material PC ABS V0 MB Weight 6 6 kg Cable length 5 m Electrical Model Home Essential Plus 11 Home Essential Plus 22 Charging mode Mode 3 C Three phase alternating current 3P N PE Supply voltage 400 V AC 10 Mains frequency 50 60 Hz Max current 16 A 3...

Страница 10: ...stalled and secured by a qualified electrician in accordance with local safety regulations and legal requirements DANGER Warning of dangerous electrical voltage Touching electrical cables can result in a fatal electric shock Only use the charging station after it has been commissioned by a qualified electrician NOTE Observe the installation instructions For installation by a qualified electrician ...

Страница 11: ...d contact an electrician or customer service for repair work Is the coupling of the charging cable clean and dry If the charging cable coupling is wet or dirty it can be cleaned with a clean and dry cloth Charging the vehicle Plug the coupling of the charging cable into the socket on the vehicle side The LED status indicator lights up yellow as soon as the vehicle is connected to the charging stat...

Страница 12: ...he supply network e g caused by a lightning strike the charging process may be briefly interrupted After the surge voltage has subsided the charging station continues the charging process independently Meaning of the LED display LED display Operating status White flashing Function test Lights green Ready to connect Lights yellow Connected to vehicle Lights blue Charging Lights red Malfunction 6 Ma...

Страница 13: ...LRT Home Essential 11 22kW operating instructions 13 16 8 CE Declaration of Conformity ...

Страница 14: ...14 16 LRT Home Essential 11 22kW operating instructions Notes ...

Страница 15: ...LRT Home Essential 11 22kW operating instructions 15 16 ...

Страница 16: ......

Отзывы: