background image

21

GB

GB

7.3   Recovery of the refrigerant

The refrigerant must always be recovered in suitable cylinders, using the 

recovery unit and following its instructions for use. 

Note

The refrigerant must not be released into the atmosphere.

7. CHARGE AND TEST OF THE SYSTEM

7.2   Final test

-  Switch on the electrical power to the air conditioner, insert the batteries 

in the remote control, press the ON/OFF starting key, and set the desired 
operating conditions.

-  After a few minutes, test the correct functioning of the system with a 

thermometer. 

When set in 

cooling mode (COOL),

 the temperature of the outlet air at 

the indoor unit must be lower than that of the inlet air by about 12-15 °C.

When set in 

heating mode (HEAT),

 the temperature of the outlet air at 

the indoor unit must be higher than that of the inlet air by about 15-20 °C.

8. DISPOSAL

8.1  Environmental safeguard information!

This equipment contains fluorinated greehouse gases covered 

by Kyoto Protocol. It should only be serviced or dismantled by 

professional trained personnel.

Directive 2002/96/EC (WEEE): Information for users

This product complies with EU Directive 2002/96/EC.

The barred bin symbol on the appliance indicates that the product, requi-

ring separate treatment to household waste after its normal working 

life, must be taken to a waste-sorting centre for electrical and electronic 

appliances or returned to the retailer at the time of purchasing a new 

equivalent appliance.

The user is responsible for taking the appliance to the appropriate waste 

collection centre at the end of its working life.

Correct waste sorting, with the discarded appliance being sent for 

recycling, treatment and compatible environmental disposal helps 

prevent any negative effects on the environment and health, and encou-

rages the recycling of product materials.

For further detailed information regarding available collection systems, 

please contact your local waste disposal service or the shop where you 

made your purchase.

8.2   Disposal rules for the old air conditioner

Before disposing of your old air conditioner, make sure that it is off and 
unplug it. The refrigerant it contains requires a special procedure for dis-
posal. Materials of value in the air conditioner can be recycled. Contact 
local authorities or the waste disposal facility for more information. 
Make sure you do not damage the pipes of the air conditioner before you 
take it to the waste disposal facility. Help protect the environment by 
following a correct, non-polluting method of disposal.

8.3  Disposal rules of the new air conditioner 

packaging

All of the air conditioner packing materials can be disposed of without 
harming the environment. The cardboard box must be cut into pieces and 
delivered to a paper collection container. The plastic and polystyrene 
packaging does not contain fluorine or hydrocarbons.
All of these materials can be deposited in a waste dump and recycled 
after proper treatment. Contact your local authorities for information on 
waste disposal.

8.4   Battery disposal

The batteries have been designed and produced with 

high quality materials and the components can be 

recycled and/or re-used.

The symbol of the crossed-out rubbish bin indicates that 

the product (batteries) at the end of its useful life must 

be handled separately from domestic waste and must be 

sent to a separate waste collection center, as provided by the European 

Community 2006/66EC, art. 20 and annex II.

If under the bin there is a chemical symbol, this indicates that the batte-

ries have a certain concentration of heavy metal.and it will be indicated 

as follows:

Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)

Содержание XECO Series

Страница 1: ...INSTALLATION MANUAL FOR EXTERNAL UNIT INSTALLATION MANUAL FOR EXTERNAL UNIT GB GB Air Conditioners Line Residential Serie XECO...

Страница 2: ...the specifications and all the information useful for the correct functioning The information contained in this publication may be subject to changes at any time and without any notice whatsoever for...

Страница 3: ...utdoor unit 5 3 Minimum operational distances of indoor unit 5 4 Minimum operational distances of outdoor unit 5 5 Distance between the units 5 6 Dimensions of the indoor unit 5 7 Dimensions of the ou...

Страница 4: ...it is pressed the air conditioner runs in automatic mode 1 1 Composition of the air conditioner The air conditioners are of the Split System type with air air heat exchange They consist of two separat...

Страница 5: ...oduct identification table The following table is for identifying the make up of the air conditioner Type Potentiality in kBtu h Model Set UI UE Outdoor Unit Indoor Unit Single HI Wall 9 XECO 0913 XEC...

Страница 6: ...stall the air conditioner in rooms where gas leakages or other flammable substances could occur near the units Maintenance operations must be carried out exclusively by quali fied technicians Do not u...

Страница 7: ...r condi tioner Avoid the use of heating equipments near the air conditioner Select the most suitable room temperature Be careful in rooms where there are children sick and or elderly people Do not pou...

Страница 8: ...with permanent ink the factory charge of refrigerant of the product the amount of additional refrigerant for the pipes the total charge of refrigerant The completed label must be placed in a visible...

Страница 9: ...ble materials Organic peroxide Exposure controls personal protection Control parameters AEL 8 h TWA 1000 ml m for each of the two components Respiratory protection For gas recovery and maintenance wor...

Страница 10: ...operations have to be done carefully because the external part of the units has not to be damaged when knifes or cutters are used to open the carton package After unpacking make sure of the unit inte...

Страница 11: ...bserve the minimum operational distances 5 2 Positioning the outdoor unit If possible avoid exposing the unit to direct sunlight particularly in early afternoon On the contrary provide for a suitable...

Страница 12: ...e positioned with a maximum gradient of 5 metres In cases where the indoor unit is installed higher than the outdoor unit with Between 3 and 5 meters must be provided an intermediate siphon to lock oi...

Страница 13: ...of the indoor unit 70 90 45 45 40 55 40 41 3 41 3 71 161 54 54 5 120 5 548 5 W D H 103 149 542 176 130 685 193 XECO 0913 W XECO 1213 W XECO 0713 XW XECO 0913 XW XECO 1813 W XECO 2413 W 55 55 55 70 70...

Страница 14: ...G Model A mm B mm C mm D mm E mm F mm G mm XECO 0913E 776 540 320 712 257 510 286 XECO 1213E 848 540 320 756 257 540 286 XECO 1813E 965 700 396 890 340 560 364 XECO 2413E 1000 790 427 920 370 610 395...

Страница 15: ...n Place the condensation water outlet so that no damage may be caused to people or things It is advisable to be able to visually check the outlet drain at the end of the piping or alternatively insert...

Страница 16: ...n near the outdoor unit in order to enable the flare to be remade if necessary Remove any burrs from the end of the pipe using a countersink This ope ration is very important in order to obtain good q...

Страница 17: ...d connection cables must be approved in conformance with IEC standards and for lengths up to 15m must have a section not less than Model Cable of alimentation Cable connection Single Hi Wall 3x2 5 mm2...

Страница 18: ...with the piping make a suitable wall ancho rage by means of a cable fastener or hose clips 6 4 4 Connection to the outdoor unit terminal board Remove the two fixing screws and take off the terminal b...

Страница 19: ...Dual Hi Wall L A B Alimentation Cable Connection cable Connection cable Connection with indoor unit L Terminal block external unit Trial Hi Wall L A B Connections with the internal unit Indoor Unit In...

Страница 20: ...nd turn the pump off If the pressure gauge set is fitted with a vacuum gauge wait at least 5 minutes then check that the vacuum in the system has been maintained If not look for the cause of the leak...

Страница 21: ...effects on the environment and health and encou rages the recycling of product materials For further detailed information regarding available collection systems please contact your local waste disposa...

Страница 22: ...and indoor unit E6 OFF 3s and blink 6 times Cooling and dehumidification compressor and outdoor fan stops while the indoor fan continues to run Heating the entire unit stops Communication cable is no...

Страница 23: ...w supply voltage 2 Overabundance of refrigerant 3 Ambient temperature is too high 4 Poor heat exchange exchanger dirty or poor air circulation 18 Reduced frequency due to overcurrent F8 OFF 3s and bli...

Страница 24: ...igh temperature protection IPM module P8 OFF 3s and blink 19 times Cooling and dehumidification compressor and outdoor fan stops while the indoor fan continues to run Heating the entire unit stops 1 C...

Страница 25: ...d 39 Abnormal outdoor fan motor L3 OFF 3s and blink 23 times The compressor stops 1 Motor wiring loose or sliced 2 Motor blocked 3 Motor damaged 4 Electronic board damaged 40 High power protection L9...

Страница 26: ...stops 1 Supply voltage less than 175 V AC 2 Four way valve wiring loose or sliced 3 Four way valve damaged 4 Electronic board damaged 47 Anomaly from zero crossing of outdoor unit U9 OFF 3s and blink...

Страница 27: ...erminals or con nectors FU Fuse BN Brow BK Black BU Blue YV Ivory GY Gray GN Green VT Violet OG Orange RD Red YE Yellow Swing Motor M Defective motor 4YV 4 way valve EKV Electronic expan sion valve C...

Страница 28: ...28 GB GB 10 XECO 1213 XECO 1813 and XECO 2413 10 WIRING DIAGRAMS...

Страница 29: ...29 10 WIRING DIAGRAMS XECO 1813D XECO 2413T GB GB...

Страница 30: ...fler 4 Way valve Strainer Electronic Expansion Valve Strainer OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT Model XECO 0913 and XECO 1213 Refrigerant pipe diameter Liquid 1 4 6 mm Gas 3 8 9 52 mm INDOOR UNIT...

Страница 31: ...31 kWh y kWh y kW kW kWh y kWh y kW kW kW kW kW kW 55 GB GB 12 REFRIGERATION CIRCUIT kWh y kWh y kW kW kWh y kWh y kW kW kW kW kW kW 55...

Страница 32: ...32 GB GB 12 kWh y kWh y kWh y kW kW kW kWh y kWh y kWh y kW kW kW kW kW kW kW kW kW 12 REFRIGERATION CIRCUIT...

Страница 33: ...33 12 REFRIGERATION CIRCUIT GB GB kWh y kWh y kWh y kW kW kW kWh y kWh y kWh y kW kW kW kW kW kW kW kW kW...

Страница 34: ......

Страница 35: ...reet Zip Town Country Slip A for user To be kept Please print in block letters GUARANTEE CERTIFICATE Slip A GUARANTEE CERTIFICATE Slip B GUARANTEE CERTIFICATE Slip C Model Serial Number Date installat...

Страница 36: ...send part C in a closed envelope to Emmeti Spa post box nr 74 Fontanafredda PN within ten days from the date of installation first startup Should the certificate not be sent within 10 days of the ins...

Страница 37: ...37 Note...

Страница 38: ...Note...

Страница 39: ...Note...

Страница 40: ...a correct disposal the different materials must be divided and collected according to the regulations in force EMMETI Spa Via B Osoppo 166 33074 Fontanafredda frazione Vigonovo PN Italy Tel 0434 56791...

Отзывы: