GASPEX MULTI
INSTALLATION MANUAL
GB
MANUAL DE INSTALAÇÃO
PT
Страница 1: ...GASPEX MULTI INSTALLATION MANUAL INSTALLATION MANUAL GB GB MANUAL DE INSTALA O MANUAL DE INSTALA O PT PT...
Страница 2: ...tion may be reproduced or distributed without the express written consent of Emmeti Warning Keep all manuals in a dry place to avoid deterioration and for future reference GB PT PT Agradecemos pela co...
Страница 3: ...system 5 2 1 Characteristics and scope 2 2 Storage 3 Installation 23 3 1 Pipes pressure loss 3 2 Fitting pressure loss 3 3 Equipment 3 4 Preparation of the pipe 3 5 Press fitting operation 3 6 Verific...
Страница 4: ...Conex es com terminais de compress o para uso com tubos pl sticos e multicamada Requisitos Copper and copper alloys Fittings with press ends for use with plastics and multilayer pipes Requirements AB...
Страница 5: ...orruga ted polymer sheath This last item is also supplied as an accessory Available sizes 16 20 26 e 32 The equipment and tools needed for installation are common with the EMMETI GERPEX and GERPEX RA...
Страница 6: ...033 1 877 0 009 1 110 22 2 222 0 412 5 461 0 104 3 072 0 035 1 966 0 010 1 163 23 2 323 0 446 5 709 0 112 3 211 0 038 2 055 0 011 1 216 24 2 424 0 482 5 957 0 121 3 351 0 042 2 145 0 012 1 269 25 2 52...
Страница 7: ...297 0 939 0 033 0 601 0 0034 0 355 23 0 710 0 152 1 744 0 322 0 981 0 035 0 628 0 0037 0 372 24 0 741 0 164 1 820 0 347 1 024 0 038 0 655 0 0040 0 388 25 0 772 0 176 1 896 0 374 1 067 0 041 0 683 0 00...
Страница 8: ...fittings can be calculated with the following formula noting the loss coefficients of individual items p v 2 p load loss Pa 0 01 mbar load loss coefficient fluid density kg m v fluid speed m s Item 1...
Страница 9: ...s with a smaller diame ter than the connector being press fitted will damage the callipers and compromise the join of the press fitted connector NO Calibrator Countersink Verify that the calibrator do...
Страница 10: ...5 x d 4 x d 26 x 3 5 x d 4 x d 32 x 3 5 x d 4 x d Cutting the pipe Cut the pipe cleanly and perpendicular to the axis of the pipe as oblique or rough cuts compromise the connection fit 90 90 90 NO Rou...
Страница 11: ...until reaching the aluminum part of the pipe with the cutter Insertion of the pipe into the connector During the insertion of the pipe into the connector pay attention that the two are lined up on the...
Страница 12: ...lowing table If the dimensions do not match the press fitting tool may not have completely closed or be worn Check if the tool is clean and that it opens and closes normally If the press fittings are...
Страница 13: ...nies the hydraulic press fitting tool 6 Always keep the hydraulic press fitting tool and callipers clean WARNING Avoid connections with cast iron or miscali brated tapered threads since high tightenin...
Страница 14: ...1 Caracter sticas e fun o 2 2 Armazenamento 3 Instala o 17 3 1 Perda de press o nos tubos 3 2 Perda de press o na montagem 3 3 Equipamento 3 4 Prepara o do tubo 3 5 Opera o de montagem press o 3 6 Ver...
Страница 15: ...nex es com terminais de compress o para uso com tubos pl sticos e multicamada Requisitos Copper and copper alloys Fittings with press ends for use with plastics and multilayer pipes Requirements ABNT...
Страница 16: ...o de pol mero ondulado de cor amarela Este ltimo item tamb m fornecido como acess rio Tamanhos di spon veis 16 20 26 e 32 O equipamento e as ferramentas necess rias para a instala o s o comuns com os...
Страница 17: ...5 213 0 095 2 932 0 033 1 877 0 009 1 110 22 2 222 0 412 5 461 0 104 3 072 0 035 1 966 0 010 1 163 23 2 323 0 446 5 709 0 112 3 211 0 038 2 055 0 011 1 216 24 2 424 0 482 5 957 0 121 3 351 0 042 2 14...
Страница 18: ...140 1 669 0 297 0 939 0 033 0 601 0 0034 0 355 23 0 710 0 152 1 744 0 322 0 981 0 035 0 628 0 0037 0 372 24 0 741 0 164 1 820 0 347 1 024 0 038 0 655 0 0040 0 388 25 0 772 0 176 1 896 0 374 1 067 0 0...
Страница 19: ...odem ser calculadas com a seguinte f rmula notando os coefi cientes de perda de itens individuais p v 2 p perda de carga Pa 0 01 mbar coeficiente de perda de carga densidade de fluido kg m v velocidad...
Страница 20: ...com um di metro inferior ao do conector a ser montado press o ir danificar as pin as e comprometer o acoplamento do conector montado press o N O Calibrador Fresadora Certificar se que o calibrador n o...
Страница 21: ...26 x 3 5 x d 4 x d 32 x 3 5 x d 4 x d Corte do tubo Cortar o tubo com precis o e perpendicular ao eixo do tubo pois corte obl quos ou imprecisos comprome tem a conex o 90 90 90 N O Corte impreciso ou...
Страница 22: ...hor rio at chegar parte de alum nio do tubo com o cortador Inser o do tubo no conector Durante a inser o do tubo no conector prestar aten o para os dois estejam alinhados no mesmo eixo e n o torcidos...
Страница 23: ...esgastada Verificar se a ferramenta est limpa e se abre e fecha normalmente Se as montagens press o ainda n o estiverem corretas necess rio levar a ferramenta de montagem press o e pin as a um centro...
Страница 24: ...equipamento 4 Verificar periodicamente o correto funcionamento do equipamento 5 Ler atentamente o manual que acompanha a ferra menta de montagem press o hidr ulica 6 Manter sempre limpas a ferramenta...
Страница 25: ...Note 25 PT PT...
Страница 26: ...Note PT PT 26...
Страница 27: ...Note 27 PT PT...
Страница 28: ...ambiente Para descarte adequado os diferentes materiais devem ser separados e transferidos de acordo com a legisla o vigentes Rev 0 01 2020 Ufficio Tecnico Clima Emmeti Spa AM U Tecnico A M EMMETI Spa...