background image

2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

Questi apparecchi sono destinati ad un uso professionale.
L’installazione, la riparazione e l’utilizzo devono essere eseguiti da
personale specializzato.

These instructions for installation are for our gas kitchens set up for
the category in the table 1 on pag. 7. The data plate is located on
the appliance, see diagram. Beware of inexpert handling.

6

· 20

Model

M74NB

M76NB

M74NBFG

M76NBFG

M74NBFE

M76NBFE

M74NBFXE

M76NBFXE

Description

Gas range 4 burners with pilot flame - open compartment

Gas range 6 burners with pilot flame - open compartment

Gas range 4 burners with pilot flame - gas oven GN 2/1

Gas range 6 burners with pilot flame - gas oven GN 2/1

Gas range 4 burners with pilot flame - electric oven GN 2/1

Gas range 6 burners with pilot flame - electric oven GN 2/1

Gas range 4 burners with pilot flame - el convection oven GN 1/1

Gas range 6 burners with pilot flame - el convection oven GN 1/1

Dimensions in mm. (LxDxH)

800 x 700 x 900

1000 x 700 x 900

800 x 700 x 900

1000 x 700 x 900

800 x 700 x 900

1000 x 700 x 900

800 x 700 x 900

1000 x 700 x 900

N.

51BS3547

51BS3547

51BS3547

51BS3547

51BS3547

51BS3547

51BS3547

51BS3547

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

0837_GB_99

- GAS KITCHENS WITH PILOT

Содержание M74NB

Страница 1: ...05 2020 0837_GB_99 High Technology Low Cost M74NB M76NB M74NBFG M76NBFG M74NBFE M76NBFE M74NBFXE M76NBFXE Instructions for installation use e maintenance GAS KITCHENS WITH PILOT...

Страница 2: ...CHARACTERISTICS 0837_GB_99 GAS KITCHENS WITH PILOT 2 20 Supplied by Date Customer Service FAX e mail...

Страница 3: ...11 5 1 15 Replacement of pilot injector of gas oven GN 2 1 11 5 2 Maintenance 11 5 3 Replacing parts 12 5 3 1 Open flame gas cock 12 5 3 2 Open flame thermocouple 12 5 3 3 Gas valve gas oven GN 2 1 1...

Страница 4: ...8 3 5 5 7 5 5 8 5 5 55 6 1 4 7 3 3 3 3 E power Gas 1 2 Electric power Electric power Data plate Data plate Electric power Data plate Data plate Gas 1 2 Data plate Gas 1 2 Gas 1 2 Gas 1 2 Gas 1 2 Data...

Страница 5: ...6 9 M M 6 9 9 9 9 9 D 0 2 Gas 1 2 Data plate Data plate Data plate Gas 1 2 Electric power Electric power Data plate Electric power Data plate Electric power Gas 1 2 Gas 1 2 Gas 1 2 Gas 1 2 1 DIAGRAM 0...

Страница 6: ...convection oven GN 1 1 Dimensions in mm LxDxH 800 x 700 x 900 1000 x 700 x 900 800 x 700 x 900 1000 x 700 x 900 800 x 700 x 900 1000 x 700 x 900 800 x 700 x 900 1000 x 700 x 900 N 51BS3547 51BS3547 5...

Страница 7: ...trical data M74NB M74NBFE M74NBFXE M76NB M76NBFE M76NBFXE M74NBFG M76NBFG S 72 11 5 0 1 60 0 529 0 394 165 Adjustable 115 55 7 18 5 Model Category Construction type Air necessary for combustion Nomina...

Страница 8: ...ustment between 150 C and 300 C is made with the thermostat The main burner is switched on from a pilot burner with safety ther mocouple The pilot burner has a piezo ignition The bottom of the oven in...

Страница 9: ...te l min The following formula is used to calculate the value of E It is important measure the power when the appliance is in standby status The calorific power value can be requested from the local g...

Страница 10: ...5 SET UP FOR OPERATION 10 20 0837_GB_99 GAS KITCHENS WITH PILOT 6 8 7 9 22 5 4 21 A 1 2 3 11 17 14 Fig 1...

Страница 11: ...unfix the injector and replace the injector with one able for the type of gas see table 1 install in reverse order After the replacement check the seal using a leack detector spray 5 1 13 Setting red...

Страница 12: ...and put in a new piece pos 14 fig 2 install in reverse order 5 3 6 Main burner gas oven GN 2 1 Remove the front lower panel by removing the fastening screws Unscrew the screws fixing the hanger pos 2...

Страница 13: ...t pos 2 fig 5 NB the nut is with left thread Loosen the bolts pos 3 fig 5 hat hold the motor pos 4 fig 5 on the oven and pull off from rear Re install in reverse order position ing in the correct way...

Страница 14: ...Attention The manufacturer declines all responsibility concern ing mistakes included in these instructions due to translating or printing errors the manufacturer also reserves the right to change the...

Страница 15: ...ppliance is not to be used for a long time clean thor oughly cas instructed in the chapter 6 7 Appliance care and fre quency of maintenance close the connecting cock of the unit and switch off any ele...

Страница 16: ...od together i e fatty dishes or vegetables containing acids Avoid damaging the stainless steel surface in particular with different metals Residues from other metals help build up the formation of che...

Страница 17: ...1 3 5 2 4 6 1 3 5 2 4 6 R2 R1 H1 H2 F2 230V 3 14 75 A 1 3 5 2 4 6 R1 R2 230V 25 7 A 1 3 5 2 4 6 R1 R2 L1 N 1 mA 2 3 4 1 mA 2 3 4 L1 L2 L3 M74NBFE M76NBFE 0837_GB_99 GAS KITCHENS WITH PILOT mA B1 B2 F...

Страница 18: ...3 H1 H2 R1 F1 MV F2 M74NBFXE M76NBFXE 0837_GB_99 GAS KITCHENS WITH PILOT mA B1 R1 F1 F2 H1 H2 MV Terminal board Commutator Heating element 2500 W Thermostat Security thermostat Green indicator light Y...

Страница 19: ...19 20 NOTES 0837_GB_99 GAS KITCHENS WITH PILOT...

Страница 20: ...idicucine it WARNING THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTU...

Отзывы: