EMKO RS PRO EPM-3790 Скачать руководство пользователя страница 5

1.Preface

1.1 General Specifications

5

EPM-3790

Optional

Standard 

Analogue Output
(0/2...10V

)

Z

Analogue Output
(0/4...20mA

)

Z

Digital Output

Digital Output

Digital Input

Forward Direction Output
Reverse Direction Output

Forward, Reverse direction 
Control for V/F Speed 
Controller

Reference Speed for  
V/F Speed Controller 

Error Input

Error detection for
V/F Speed Controller

Power Supply
Input

Standard

Optional Supply Input

24 V 

W

 (-%15;+%10)

50/60Hz

Universal Supply Input

1

00-240 V 

V

 (-%15;+%10)

50/60Hz

     EPM-3790 series units are designed for controlling the speed and direction of the motor as a 
control panel for V/F Speed Controllers in industry. They can be used in many applications with 
their easy use and operation with their ramp properties.

Содержание RS PRO EPM-3790

Страница 1: ...w limit and set value high limit boundaries Adjustable ramp up and ramp down time Forward Reverse direction outputs and error input for V F Speed Controller 0 2 10V Voltage output or 0 4 20mA Current...

Страница 2: ...ed Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in these...

Страница 3: ...3 6 ANALOGUE OUTPUT DIGITAL INPUT OUTPUTS CONNECTION WITH V F SPEED CONTROLLER 3 6 1 DEVICE WITH 3 6 2 DEVICE WITH 4 FRONT PANEL DEFINITION AND ACCESSING TO THE MENUS 4 1 OBSERVATION OF THE SOFTWARE...

Страница 4: ...EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4 2007 EMC Generic Emission Standard...

Страница 5: ...roller Reference Speed for V F Speed Controller Error Input Error detection for V F Speed Controller Power Supply Input Standard Optional Supply Input 24 V W 15 10 50 60Hz Universal Supply Input 100 2...

Страница 6: ...completely 1 4 Maintenance Repairs should only be performed by trained and specialized personnel Cut power to the device before accessing internal parts Do not clean the case with hydrocarbon based so...

Страница 7: ...eep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit...

Страница 8: ...tion 2 2 Front View and Dimensions of EPM 3790 Unit 77mm 3 03 inch 35mm 1 38 inch Mounting Clamp Front Panel IP65 protection NEMA 4X Panel surface maximum tnickness 15mm 0 59 inch 8 Digital Potentiome...

Страница 9: ...2 3 Panel Cut Out 110 mm 4 33 inch min 50 mm 1 97 inch min 29mm 1 14 inch 71mm 2 79 inch Maximum 15mm 0 59 inch 58 5 mm 2 30 inch 4 mm 0 16 inch 9...

Страница 10: ...unting the device in your panel make sure that the cut out is of the right size 2 Insert the device through the cut out If the mounting clamps are on the unit put out them before inserting the unit to...

Страница 11: ...panel cut out from the front side 2 Insert the mounting clamps to the holes that located left and right sides of the device and make the unit completely immobile within the panel Before starting to re...

Страница 12: ...nstaller to ensure that the configuration is correct Device parameters has factory default values These parameters must be set according to the system s needs Only qualified personnel and technicians...

Страница 13: ...15 10 50 60Hz 2VA 24VZ 15 10 2W ERR OUT OUT IN IN VOLTAGE 0 2 10V or Z 0 4 20mA Z Forward Direction Output Reverse Direction Output 10 30V Input Z Error Input 3 2 Electrical Wiring Diagram Electrical...

Страница 14: ...3 4 1 5 6 7 8 9 10 11 12 L N 100 240VV 15 10 2 VA 50 60Hz 0 2 10VZ OUTPUT GND ERR OUT OUT IN 2 P N ESM 3710 6 09 0 1 00 00 1 0 0 0 Y ca OUTPUT 12 V W 15 50 60Hz 1 5VA 3 4 1 5 NO NC C 10A 250V V 6 7 8...

Страница 15: ...must be added to the supply voltage input Power supply switch and fuse must be put to a place where user can reach easily Power supply switch must be two poled for seperating phase and neutral On Off...

Страница 16: ...5 EPM 3790 Galvanic solation Test Values of Unit Supply Voltage Input 1 2 Ground 11 Digital Input Output 7 8 9 12 2000V V 2000V V 2000V V 2000V V EPM 3790 1 500V V EPM 3790 2 7 8 9 12 Analogue Output...

Страница 17: ...utput Fwd Stop Rev Stop 10 30 VZ GND AIN 0V Output V F Speed Controller Error Output GND 0 2 10VZ OUTPUT M 3 V U V W PE 3 6 2 Devices with 0 4 20mA Z Analogue Output 2 EPM 3790 Y ca 3 4 1 5 6 7 8 9 10...

Страница 18: ...sed for 2 seconds continuously increment and decrement number become 10 if pressed for 4 seconds continuously increment and decrement number become 100 if pressed for 6 seconds continuously increment...

Страница 19: ...value according to the and parameters i 4 2 1 Changing and Saving Set Value While The Motor is Running 4 2 Changing and Saving Set Value When SET button is pressed SET value is shown on the display an...

Страница 20: ...meter value Decimal Point Position Parameter Default 0 Decimal point position is determined with this parameter It can be adjusted from 0 to 3 Power On Output Control Parameter Default 3 When power on...

Страница 21: ...r drCS 0 REVERSE DIRECTION For drCS 1 FORWARD DIRECTION For drCS 0 REVERSE DIRECTION For drCS 1 FORWARD DIRECTION For drCS 0 REVERSE DIRECTION For drCS 1 For 0V 1 2 Set V Set mA 0mA 1 2 Figure 4 3 Pow...

Страница 22: ...button While the motor is running and the unit is on operation screen Decrement button is disabled Analogue output is directly adjusted to minimum Set value when decrement button is pressed Analogue o...

Страница 23: ...t can be adjusted from 0 to 4095 When pressing button on screen adjustment value is seen on screen The value on the screen should be adjusted with Incremet and decrement button until 10 00V or 20 00mA...

Страница 24: ...it Parameter Set Low Limit Parameter SET P SET P Direction Change Delay Time Parameter SET P Direction Selection Parameter Power On Output Control Parameter SET P SET P Increment Button Parameter For...

Страница 25: ...is pressed for 10seconds P led starts to blink If programming section accessing password is different from 0 programming section accessing screen is observed Note 1 If programming section accessing pa...

Страница 26: ...lly Programming Screen Programming Screen Programming Screen Programming Screen Press Set button for accessing to the next parameter Parameter is accessed by pressing increment button If set button is...

Страница 27: ...utomatically Press Set button for accessing to the next parameter Parameter is accessed by pressing increment button If set button is pressed next parameter is shown Press Set button for saving the pa...

Страница 28: ...amming Screen Programming Screen Programming Screen Programming Screen Direction Selection Parameter Value Reverse Direction Selected Press Set button for accessing to the next parameter Parameter is...

Страница 29: ...s to operation screen automatically Programming Screen Programming Screen Programming Screen Programming Screen Press Set button for accessing to the next parameter Parameter is accessed by pressing i...

Страница 30: ...urns to operation screen automatically Programming Screen Programming Screen Programming Screen Programming Screen Press Set button for accessing to the next parameter Parameter is accessed by pressin...

Страница 31: ...de for 20 seconds device turns to operation screen automatically Programming Screen Programming Screen Programming Screen Programming Screen Press Set button for saving the parameter value Parameter i...

Страница 32: ...accessed otherwise parameter is seen If no operation is performed in Programming mode for 20 seconds device turns to operation screen automatically Programming Screen Programming Screen Programming Sc...

Страница 33: ...operation screen automatically Programming Screen Programming Screen Programming Screen Parameter is accessed by pressing increment button If set button is pressed next parameter is shown Press Set bu...

Страница 34: ...amming Screen 1 Please refer to Figure 4 6 forTup andTdown time When Start Stop button is pressed Set value is seen on display Start led lights on selected digital output is being active and analogue...

Страница 35: ...35 5 Failure Message in EPM 3790 Unit When Error input is being active Error led starts to blink The Unit passes to the stop position Digital Potentiometer SET EPM 3790 P...

Страница 36: ...digits LED Display LED Start Red Forward Direction Red Reverse Direction Red Error Red P Red 3 mm Led Control Panel For V F Speed Controller 100 240 V V 15 10 15 10 24VZ 15 10 2W Electrical Specificat...

Отзывы: