Page 27 / 30 EZM7750_ENG_VER11
Set1
0
Out2
Out1
Out1
Out1 pulse time!=0
Out1 pulse time =0
Out2 pulse time = 0 or Out2 pulse time!=0
Set2
Reset
Set1
0
Out2
Out1
Out1
Out1 pulse time!=0
Out1 pulse time =0
Out2 pulse time = 0 or Out2 pulse time!=0
Set2
Reset
Counting Direction : P --> 0 (Counting to downwards)
Output function - 7
Counting Direction : 0 --> P (Counting to upwards)
Timer
Chronometer
When the actual value is equal or bigger than the SET1 value, the OUT1 becomes
active. If the Out1 was selected periodical, Out1 becomes inactive at the end of the
determined time. If the output was selected indefinite, the output becomes inactive
when the actual value reaches to SET2 value.
When the actual value reaches to SET2 value, actual value becomes “0” and OUT2
becomes active. OUT2 is active when the actual value reaches to SET2 value.
NOTE: Out1 and Out2 outputs becomes active reverse.
When the actual value is equal or less than the SET1 value, the OUT1 becomes
active. If the Out1 was selected periodical, Out1 becomes inactive at the end of the
determined time. If the output was selected indefinite, the output becomes inactive
when the actual value reaches to “0”.
When the actual value reaches to “0”, SET2 appoints to actual value becomes SET2
value and OUT2 becomes active. OUT2 is active when the actual value reaches to “0”.
NOTE: Out1 and Out2 outputs becomes active reverse.