4.3 Parameters List:
COUNTER and TOTALIZER COUNTER PARAMETERS:
PRO-01
Input type and function’s
0- UP Counting by a rising edge of Ch-A.
1- DOWN Counting by a falling edge of Ch-A.
2- UP Counting by a rising edge of Ch-A and DOWN Counting by a falling edge Ch-B.
3- UP Counting by a rising edge of Ch-A and Ch-B.
4- UP Counting by a rising edge of Ch-A when Ch-B=0. DOWN Counting by a rising edge Ch-A
when Ch-B=1.
5- 1 x Incremental encoder counting
6- 2 x Incremental encoder counting
7- 4 x Incremental encoder counting
PRO-04
Contact Bounce for electrical noise. Adjustable from 0 to 250 miliseconds.
PRO-06
Configuration for output functions. Refer to “Output Functions” for detail.
PRO-14
Output Function for module-1
0- Normally non-energised
1- Normally energised
PRO-15
Output Function for module-2
0- Normally non-energised
1- Normally energised
PRO-16
Energising time for Module-1. Adjustable from 0000.00 to 0099.99 seconds. Refer to “Output
Functions” for detail.
PRO-17
Energising time for Module-2. Adjustable from 0000.00 to 0099.99 seconds. Refer to “Output
Functions” for detail.
PRO-19
Selection counting direction.
0- 0 to PRESET
1- PRESET to 0
PRO-20
Decimal point position of the display.
0- 000000, 1- 00000.0, 2- 0000.00, 3- 000.000, 4 -00.0000
PRO-21
It’s determinates, actual value on the display saved or unsaved to memory when the energy
breaking.
0- Saved to memory. When the device energised, counting become from saved actual value.
1- Unsaved to memory. When the device energised, counting become from “0”.
PRO-22
This parameter determinates, used or not used SV1 value as an OFFSET value. If parameter value
is “1”, Sv1value is SV2+SV1.
0- Absolute value, 1- Offset value
PRO-23
Slave Address for serial communication bus. Adjustable from 1 to 247. The parameter value is “1”
for single device on the serial communication bus.
PRO-24
Configuration for MODBUS protocol.
0- MODBUS protocol is ASCII .
1- MODBUS protocol is RTU (Binary) .
PRO-25
Parity: 0-None, 1-Even, 2-Odd
PRO-26
Baud Rate: 0-1200 Bps, 1-2400 Bps, 2-4800 Bps, 3-9600 Bps, 4-19200 Bps
PRO-27
Stop Bits: 0- 1 Stop bit, 1- 2 Stop bit
PRO-28
Protection for RESET, SET-1 and SET-2 buttons on the front panel.
The parameter is adjustable 0 to 5.
0-Non protection. All buttons are active.
1-Only protection for RESET button is active.
2-Protection for SET1 and SET2 buttons are active.
3-Protection for SET1, SET2 and RESET buttons are active.
4-Only protection for SET1 button is active.
5-Only protection for SET2 button is active.
PRO-30
Multiplication factor for input counting. The parameter is adjustable from 01.0000 to 99.9999.