9. Specifications
Device Type
: Hatcher Controller
Housing&Mounting
: 76 mm x 34.5 mm x71 mm Plastic housing for panel
Panel cut out is 71 x 29 mm.
Protection Clas
: NEMA 4X (Ip65 at front,Ip20 at rear).
Weight
: Approximately 0.2 Kg
Enviromental Ratings
: Standart,indoor at an altitude of less than 2000 meters with
none condensing humidity.
o
o
o
o
Storage / Operating Temperature
: -40 C to +80 C / -30 C to +80 C
Storage / Operating Humidity
: 90 % max. (None condensing)
Installation
: Fixed installation
Overvoltage Category
: II.
Pollution Degree
: II, office or workplace, none conductive pollution
Operating Conditions
: Continuous
Supply Voltage and Power
:
: 115
: 24
: 24
: 10-30
Thermoresistance Sensor Input
: PT-100 (IEC751) (ITS 90)
Accuracy
: ± 1 % of full scale for thermoresistance
Sensor Break Protection
: Upscale
Sampling Cycle
: 3 samples per second
Control Form
: ON / OFF or PID
Relay Outputs
: 5
A@250 V
V
at Resistive Load (Heating Output)
: 3 A@250 V
V
at Resistive Load
(Alarm and Egg tray rotator output)
(Electrical Life : 100.000 operation (Full Load))
Display
: 14 mm Red 4 digit LED Display
o
o
LED Displays
: S (Yellow), P (Yellow), C (Green), F(Green), Alarm (Red),
Egg Tray Rotator Output (Red), Heating Output (Red),
Internal Buzzer
: 83dB
Upprovals
: ,
230V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
Z
1.5W
V
±
V
±
V
±
W
±