13
Device Type
Housing & Mounting
Protection Class
Weight
Environmental Ratings
Storage / Operating Temperature
Storage / Operating Humidity
Installation
Overvoltage Category
Pollution Degree
Operating Conditions
Supply Voltage and Power
Temperature Sensor Input
NTC input type
PTC input type
Thermocouple input type
Thermoresistance input type
Accuracy
Cold Junction Compensation
Sensor Break Protection
Sampling Cycle
Control Form
Relay Output
Optional SSR Drive Output
Display
LED
Internal Buzzer
: Temperature Controller
: 76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cut-out is 71x29mm.
: NEMA 4X (Ip65 at front, Ip20 at rear).
: Approximately 0.20 Kg.
: Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity.
: -40 C to +80 C / -30 C to +80 C
: 90 % max. (None condensing)
: Fixed installation
: II.
: II, office or workplace, none conductive pollution
: Continuous
:
: 115
: 24
: 24
:10 - 30
: NTC, PTC, TC, RTD
: NTC (10 k
@25 °C )
: PTC (1000
@25 °C )
: J, K (IEC584.1) (ITS 90)
: PT-100, PT-1000 (IEC751) (ITS 90)
: ± 1 % of full scale for thermoresistance
: Automatically ± 0.1°C / ± 1°C
: Upscale
: 3 samples per second
: ON / OFF
:
A@250 V
for Resistive load (
Output)
(Electrical life : 100.000 switching at full load)
: Maximum 20mA, Maximum 17V
: 14 mm Red 4 digits LED Display
: S (Green), P (Green), C (Yellow), F(Yellow),
Compressor Output (Red), Heating Output (Red)
: 83dB
:
o
o
o
o
o
o
W
W
³
16(8)
V
Approvals
230V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
( %15) 50/60Hz - 1.5VA
V
1.5W
Z
Z
V
V
V
W
±
±
±
±
Compressor
7. Specifications
,
ENGLISH