6.1.6. WATER SPRAY PARAMETERS
The below parameters is can be used If Relay2 Output function selection parameter is selected as a 'WATER'
Output Time(min/sec)(Default =0):
Relay2 output on time value is adjusted wtih this parameter.
This parameter value is can be adjusted from 00:00 to 99:00 min/sec.
For changing parameter value first press to ENTER button and minute value is can be adjusted with
increment and decrement buttons, after second press to ENTER button second value is can be adjusted with
increment and decrement button, after third press to ENTER button parameter value is saved.
Output Period(hour/min)(Default =0):
Relay2 Output period time value is adjusted with this parameter.
This parameter value is can be adjusted from 00:00 to 24:00 hr/min.
For changing parameter value first press to ENTER button and hour value is can be adjusted with increment
and decrement buttons, after second press to ENTER button minute value is can be adjusted with increment
and decrement button, after third press to ENTER button parameter value is saved.
ENG EGG HATCHER 02 V01 04/16
24