6.1.4. TEMPERATURE ALARM PARAMETERS
Function Select(Default =High Alarm):
Alarm type is selected with this parameter.
This parameter can be adjusted as a High Alarm, Low Alarm, Band Alarm or Range Alarm.
Set Value (°C)(Default =50)
Alarm set value is adjusted with this parameter.
This parameter is can e adjusted between Min temperature alarm set parameter value to Maksimum
temperature alarm set parameter value.
Hysteresis(°C)(Default =0.1):
Hysteresis value for alarm output is can be adjusted with this parameter.
This parameter value can be adjusted from minimum value of device scale to temperature alarm set
maximum parameter value.
Min. Set (°C)(Default =-20):
Temperature alarm set value can not be lower than this value. This parameter
value can be adjusted from minimum value of device scale to Max. Set value parameter
Max. Set (°C)(Default =80):
Temperature alarm set value can not be greater than this value. This parameter
value can be adjusted from Min. Set value parameter to maximum value of the device scale.
Alarm Delay (minute)(Default =0):
Temperature Alarm On Delay Time can be defined with this parameter. It
can be adjusted from 0 to 99 minutes.
Starting Alrm Delay(minute)(Default =0):
When power is first applied to the device, this time delay must be
expired for activation of temperature alarm. It can be adjusted from 0 to 99 minutes.
ENG EGG HATCHER 02 V01 04/16
22