background image

TB-6594

 Page 5 of 12

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

Features and Components

Figure 3.  SmartLog Pro™ features and components

A

B

C D

E

F

G

H

I

J

K

L

M
N
O

Содержание SmartLog Pro 50780

Страница 1: ...r exceeds the set limits the SmartLog Pro will indicate failure via audio and visual alarms Use the included relay terminal to promote access control for passed tests The SmartLog Pro can also be netw...

Страница 2: ...tem Overview 4 Item and Accessories 4 Packaging 5 Features and Components 6 Installation 6 Hardware Setup 7 10mm Wrist Cord Adapter 8 Relay Terminal 8 Network Setup 9 Test Limit Configuration 10 TEAM5...

Страница 3: ...artLog Pro SmartLog Pro PC with TEAM5 Software Supervisor Department Manager Department Manager Department Manager Figure 2 Illustration of the SmartLog Pro System collecting and transferring ESD data...

Страница 4: ...ator for Testers Use the SmartLog Pro along with the TEAM5 Software to automate the collection of employee ESD testing This software is offered in two tiers TEAM5 and TEAM5 Enterprise Click here to vi...

Страница 5: ...TB 6594 Page 5 of 12 2016 DESCO INDUSTRIES INC Employee Owned Features and Components Figure 3 SmartLog Pro features and components A B C D E F G H I J K L M N O...

Страница 6: ...the tinned wire termination of the included ground cord to this terminal Connect the ring terminal termination of the cord to equipment ground This connection will remove any static charge from the u...

Страница 7: ...clear the clip at the base of the plunger s shaft when inserting into the jack 6 Connect the SmartLog Pro to the bracket Use the included thumbscrew to secure the SmartLog as shown below Figure 5 Secu...

Страница 8: ...Ethernet communication module DYNAMIC IP PROCEDURE 1 Verify that the Ethernet cable is securely connected to your network and SmartLog Pro The LEDs on the Ethernet port will illuminate when a connect...

Страница 9: ...quired to establish communication between the SmartLog Pro and the TEAM5 Server Software Figure 13 Locating the IP address in the Admin Menu Figure 14 Locating the Newtork button in the Admin Menu Fig...

Страница 10: ...tion Software on the market When used with the EMIT SmartLog TEAM5 allows manufacturers and assemblers to automate the collection of employee ESD testing It has a set of robust employee management fun...

Страница 11: ...if using proximity badges See Figure 20 2 Follow the prompt on the SmartLog s display 3 When performing a footwear test be sure to place both feet on the dual foot plate one foot per plate NOTE Keep t...

Страница 12: ...Adapter Power Input 100 240VAC 50 60 Hz Power Output 5VDC 3 0A Cable Length 5 ft 1 5 m Operating Temperature 70 F to 85 F 21 C to 30 C for 1 gigohm test limit 41 F to 85 F 5 C to 30 C for all other te...

Страница 13: ...EMIT Smart ESD Process Control Smart ESD Process Control 000 Checkout Products What s New Videos SmartLog V5 FAQ http emit descoindustries com 1 of 5 6 3 2016 10 45 25 AM...

Страница 14: ...trol Monitors Ionization Testers Access Control Data Acquisition Measurement Factory Closeouts Shop from our other Desco Industries websites Europe United Kingdom Asia http emit descoindustries com 2...

Страница 15: ...EMIT Smart ESD Process Control http emit descoindustries com 3 of 5 6 3 2016 10 45 25 AM...

Страница 16: ...EMIT Smart ESD Process Control http emit descoindustries com 4 of 5 6 3 2016 10 45 25 AM...

Страница 17: ...Policy Terms Conditions Our Factories Additional Resources Technical Information Resources Ask an ESD Question Find a Sales Rep or Reseller Reseller Registrations Site Map Sign up for email updates g...

Отзывы: