background image

EMIT WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

EMIT EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

www.DescoEMIT.com

TB-6566 Page 1 of 6      

 

 

 

 

 

 

 

 

 

                 Revision June 2009

 

 

 

 

 

 

 

 

 

 

 

                                               © 2009 DESCO INDUSTRIES INC.

 

 

 

 

 

 

 

 

 

 

 

 

 

                       Employee Owned

Limit Comparator - Instructions for Use

TECHNICAL BULLETIN TB-6566

Made in America

Item 

50421

 X3 Limit Comparator

DESCRIPTION

PACKAGING

1 Limit Comparator
2 Test Leads, Banana to Banana
1 NIST Certifi cate of Calibration

OPERATION

Testing Footwear Circuit, refer to fi gure 1.

To complete the footwear test, you will need to test the 
low and high limits. Refer to the dipswitch setting on the 
left side of the testers for footwear test ranges. 
Manufacturer’s suggested default test range is 750K 
low and 35Meg high for the US and Europe.

Do not power down tester, remove stereo cable from 
bottom right jack of tester labeled “FOOTPLATE” and 
connect the stereo lead from model 50421 to the jack 
labeled “FOOTPLATE”. 

Testing Low Circuit

 – If the tester’s low range is set to 

750K. Set the knob 
on model 50421 to 
the “750K LOW” 
position. Touch the 
TEST contact on 
the tester and you 
should get a red 
LED for the left and 
right foot. Disre-
gard the test result 
for the wrist strap, 
if the wrist strap 
circuit is on. 

Set the knob on model 50421 to “750K Pass”, touch the 
TEST contact on the tester and you should get a green 
LED for the left and right of the foot.

Отзывы: