INSPECTION

Carefully check the shipment against the bill of lad-
ing. Make sure all chassis, wall sleeves, and louvers
(as well as any options) have been received. Inspect
each component for damage. The carrier must make
proper notation on the delivery receipt of all damage
identified and complete a carrier inspection report.
Concealed damage must be reported to the carrier
within 15 days of the receipt of the shipment.

IMPORTANT: 

The purchaser must notify the EMI

traffic department of all damage and is responsible
for filing any necessary claims with the carrier.

APPLICATION LIMITATIONS

The VPAC/VPHP 30-36 should be installed in
accordance with all national and local safety codes.

Minimum and maximum operation conditions must be
observed to assure maximum system performance
with minimum service required. Refer to table below
for application limitations of the VPAC/VPHP 30-36.

CAUTION

Avoid possibility of electric shock and personal in-
jury. Disconnect all power before removing chas-
sis or performing any cleaning, servicing, or main-
tenance.

GENERAL INSTALLATION

Enviromaster International recommends installing the
VPAC/VPHP 30-36 before any carpentry work is
started for the enclosure. It is very important for proper
air flow and sound levels that a minimum clearance of
6” between the enclosure and the chassis be main-
tained. It is also very important that the rough opening

in the wall for the wall sleeve and louver be the cor-
rect dimension and in the exact position necessary
for installation. 

(Figure 1)

The platform height should be the same level as the
bottom of the wall opening. Because wall sleeve
depths can vary depending on overall wall thickness,
it is critical that wall thickness be determined before
ordering the wall sleeve. 

(Figure 2)

 Consult factory

for available wall sleeve sizes.

1. Install 1/2” x 1/2” or 1” x 1” foam tape (supplied)
to the unit condenser top and sides to seal against
the wall sleeve. 

(Figure 3)

FIGURE 3 - INSULATION & WEATHER ANGLES

Install supplied
1/2” x 1/2” foam
insulation along
top and sides of
condenser box.
(

I M P O R TANT:

Position as far
forward toward
outdoor side as
possible.)

Weather Angle

Position (One on

each side)

APPLICATION LIMITATIONS

Cool

Heat

115

75

DB/WB

DB

DB/WB

DB

Cool

Heat

Cool

Heat

67/57

50

90/72

80

Minimum

Maximum

Outdoor Ambient Air Temperature °F

Indoor Ambient Air Temperature °F

Cool

67

Minimum DB

Maximum DB

Exterior Wall

Wall Sleeve

Assembly

Cross Section

of Typical Wall

½” x ½” Foam Gasket

Overall Wall

Thickness

Wall Sleeve

Outdoor Louver

Drip edge will
extend outside
exterior wall
when installed
to guide con-
densate away
from building

Lag Holes

(4 Per Side)

Wall Sleeve Depth = Overall Wall
Thickness - 1.25” (Louver Depth)

FIGURE 2 - DETERMINING WALL SLEEVE DEPTH

Interior Wall

Содержание VPAC30

Страница 1: ...S Motors are thermally protected PSC type Air stream surfaces are insulated with 1 4 inch fiberglass or 1 8 inch volara The evaporator fan is a forward curved type directly mounted to the motor shaft...

Страница 2: ...uld result in serious injury or electrical shock All field wiring must be done in accordance to NEC and local codes Check the unit rating plate for circuit ampacity and breaker s or fuse size s Use on...

Страница 3: ...nd sound levels that a minimum clearance of 6 between the enclosure and the chassis be main tained It is also very important that the rough opening in the wall for the wall sleeve and louver be the co...

Страница 4: ...ressure e s p Speed tap changes may need to be made from factory settings and Envi FIGURE 5 RETURN AIR ACCESS PANEL NOTE Available with solid doors if separate intake is used Access Panel Frame Frame...

Страница 5: ...an limit the heat ing or cooling range of the thermostat A non mer cury electronic thermostat is available if needed Please contact the factory for more information SELECTING A COMPATIBLE THERMOSTAT W...

Страница 6: ...fan will continue to run to aid in the defrost process ELECTRIC HEAT OPERATION Place the thermostat system switch in heat mode Ad just the set point temperature above the room tem perature The electri...

Страница 7: ...connections Terminal ends that are loose will eventually fail causing a loss of performance or worse 5 Check fan motors and blower assemblies Some units may require a drop of light oil to motors and...

Страница 8: ...Max HACR Number Amps HP RLA LRA Amps HP Amps Voltage Breaker 30 208 230 60 1 1 7 0 25 14 73 3 0 5 18 7 197 22 3 35 36 208 230 60 1 1 7 0 25 16 3 88 3 0 5 21 197 25 1 40 VOLTS HZ PH M C A Condenser Fa...

Отзывы: