2
Installation Instructions
1.
Disconnect all power to the unit by opening and tagging
all power-supply disconnects to the unit.
2.
Remove the front access panel to expose the compressor
capacitor(s).
START ASSIST KIT INSTRUCTIONS
Figure 3 - S1C/S2C units
Figure 4 - S1C6 Only
a
.
Loosen the screws on left and right sides of the
front panel. (Do not remove these screws.)
b
.
Remove the screws on the front of the panel.
c
.
T
o remove front panel, slide front panel forward
to clear side screws and remove.
S1C Shown
240000027
Drill Screw
through
mounting
hole in Wire
Tie
240000062
Wire Tie
fastened
around
Start Assist
capacitor
240001694
Start Assist
Capacitor
Compressor
Split Capacitor
For S1C6, repeat steps a,b,& c of S1C/S2C
d.
Secure the Start Assist Capacitor to the slanted leg
of the coil support brace using the wire tie and drill
screw provided. The Capacitor must be mounted
with the wires on the top as shown in photo. Mount
in such a way that the Capacitor is not in contact
with the bottom of the unit.
Figure 5 - Top Discharge Units
4 screws on
front panel
a. Remove 4 screws on front panel and lift panel off.
3.
Read and follow instructions on all WARNING or
CAUTION labels.
4.
Locate compressor split capacitor, (marked “Herm”,
“Fan”, “C”). Refer to wiring diagram supplied with kit.
Note:
For S2C, T2C, T3C and T4C units, there is a separate
capacitor for each compressor.