9
English
FEATURES
UNLOADER VALVE
When the maximum air tank pressure is obtained, the unloader
valve (H) will blow-off. This will cause the compressor to exhaust
the air to the atmosphere and not the tank.
Manual Lock:
The manual lock allows you to manually unload the
compressor with air pressure in the air tank. To operate the manual
lock:
Rotate the manual lock unloader lever to the
OPEN
H
CLOSED
H
open
position to prevent air tank pressure
buildup. Rotate manual lock unloader lever to
the
closed
position after starting the motor to
allow air tank pressure to build.
NOTE:
Air will
not build in tank when manual lock unloader
lever is in the
open
position.
SAFETY VALVE
This valve (I) is designed to prevent system failures
I
by relieving pressure from the system when the
compressed air reaches a predeter mined level. The
valve is preset by the manu facturer and must not be
removed or modified in any way.
AIR INTAKE FILTER
The filter (A) is designed to clean air entering the pump.
A
To ensure the pump continually receives a clean, cool,
and dry air supply the filter must always be clean and
the filter intake must be free from obstructions.
AIR TANK DRAIN VALVES
The drain valve (J) is used to remove
J
moisture from the air tank after the air
compressor is shut off.
AIR TANK PRESSURE GAUGE
The air tank pressure gauge (D) indicates air
E
F
D
pressure in the air tank.
REGULATED PRESSURE GAUGE
The regulated pressure gauge (E) indicates
the air pressure available at the outlet side of
the regulator. This pressure is controlled by the
regulator and is always less or equal to the air
tank pressure.
REGULATOR
The regulator knob (F) controls the air pressure coming from the air
tank.
To Adjust Regulator:
1. Pull regulator knob (F) out.
2. Turn knob clockwise to increase regulated pressure and
counterclockwise to decrease regulated pressure.
3. When desired pressure is shown on the regulated pressure
gauge push knob in to lock.
INSTALLATION
Assembly (Fig. 1)
INSTALLING HOSES
WARNING:
Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
Содержание K15A-8P
Страница 78: ......
Страница 79: ......
Страница 80: ...Emglo Air Compressors 701 East Joppa Road Towson MD 21286 NOV06 Form No A21302 K5HGA 8P Copyright 2006 EMGLO...