14
English
2. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank, see
Draining Air Tank
under
Maintenance
.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING:
Risk of bursting.
Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk
of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure
On/Off switch is in the OFF position
.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE:
All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE:
Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE:
Any service operations not included in this section should be
performed by an EMGLO factory service center or an EMGLO autho-
rized service center.
Maintenance Chart
Procedure
Daily
Weekly
Monthly
1 year or
200 Hours
Check safety valve
X
Inspect air
X
Drain air tank***
X
Check pump oil level
X
Change pump oil**+
X
Oil leak inspection
X
Inspect drive belt
X
Check drive belt tension
X
Check pulley/flywheel
alignment
X
Check for unusual noise/
vibration
X
Check for air leaks*
X
Clean compressor exterior
X
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation.
Thereafter, when using
EMGLO
Synthetic Blue compressor oil, change
oil every 200 hours of operation or once a year, whichever comes first.
*** Drain tanks daily or after four hours of use.
+ Perform more frequent in dusty or humid conditions.