926001 en ma 2013

Konformitätserklärung 
Conformity declaration
Déclaration de conformité

ebro Electronic GmbH  
Peringerstraße 10
D-85055 Ingolstadt

erklärt in alleiniger Verantwortung, dass das Produkt
declares in sole responsibility that the product
déclare sous sa seule responsabilité que le produit

Geräteart:
Type of device:
Type d‘appareil:

Typ: 
Type: 
Modèle:

auf das sich diese Erklärung bezieht, mit der folgenden Richtlinie  
übereinstimmt:
to which this declaration refers, complies with the following guideline:
auquel cette déclaration se réfère, est conforme aux directive

Prüfstellen:
Inspected by:
Organisme de con-
trôle:

Robert Teich  
G e s c h ä f t s f ü h r e r
Managing direc tor
Directeur gérant

Richtlinie:
Guideline:
Directive:

SCHWILLE Elektronik
Produktions- u. Vertriebs GmbH
Benzstrasse 1A
85551 Kirchheim

EMV-Richtlinie 2004/108/EG
EMC-Guiedeline 2004/108/EG
CEM-Directive 2004/108/EG

T h e r m o m e t e r
T h e r m o m e t e r
Thermomètre

TFX Serie

Ingolstadt, 03.11.2004

Содержание Ebro TFX 926001 Series

Страница 1: ...926 001 DIGITAL THERMOMETER MANUAL 926001 en ma 2013 Thermometer TFX Serie...

Страница 2: ...that this product ful lls CE guidelines ed by NSF exept TFX 430 ed by UL This product fulfills the guidelines in accordance with EN 13485 Suitability S Storage T Transport Location A Food storage and...

Страница 3: ...ration 1 4 1 Switching on thermometer 1 4 2 Display 1 4 3 Measuring temperature 1 4 4 Measurement memory 2 4 4 1 Retrieving memory contents 2 4 4 2 Storing current value 2 4 4 3 Deleting measurement m...

Страница 4: ...fety notes t Never expose the device to high tem peratures 60 C 140 F t Under no circumstances measure live components with this device and external sensors t Do not use the device in explosion endang...

Страница 5: ...8 0 Fax 0841 9 54 78 80 E mail info ebro de Internet http www ebro de Parts list Thermometer with t Sensor cate t Instruction manual t For accessories see appendix I 1 3 Cautions The thermometer TFX s...

Страница 6: ...asu rement precision and linearity over the entire measurement range You may attach a range of ebro sensors to the thermometer TFX 410 1 and TFX 430 selecting the one most suitable for your technical...

Страница 7: ...s dis played for approx 1 second 3 Release the ON OFF key 2 as soon as device model TFX is displayed Then keep the lower key depressed until USER followed by MENU is displayed The device now enters th...

Страница 8: ...he automatic switch off if prolonged measurements are required with the model TFX 420 430 ALARM Tu r n a l a r m f u n c t i o n ON Alarm function turned on OFF Alarm function Press centre key Turn al...

Страница 9: ...ent menu option with the down key 5 Exit the menu with the ON OFF key 2 The device switches AL HI Upper limit value of desired range Press centre key unblock Press left right keys increase decrease up...

Страница 10: ...itches to measuring mode and the first measurement reading is displayed in C The thermometer is now ready for use If an error message is displayed please refer to chapter 6 What do I do if 4 2 Display...

Страница 11: ...eous measurements Wait until the measured value has stabilised The trend display shows a downward pointing triangle for decreasing 4 temperatures and an upward pointing triangle for increasing 3 tempe...

Страница 12: ...ed along with the lowest measurement of the current measu ring Press the key MIN MAX again MAX is displayed along with the largest measurement value in the current measuring Press MIN MAX again to ret...

Страница 13: ...or downwards by pulling at the plug in connector Do not turn 3 Plug in a new probe or extension cable where required E n s u r e the connection is secure The connector must be engaged 4 Slide the prot...

Страница 14: ...ring range exceeded Probe defective Plugin connection jack plug Consider measuring range Call service Check connection plug has to snap in Below measuring range Short circuit of sensor Consider measur...

Страница 15: ...ration t The calibrated thermometer will be returned within one week 8 Servicing and waste disposal 8 1 Cleaning Clean the device with a damp cloth Do not use any solvents such as Aceton as they corro...

Страница 16: ...oth plastic plugs 1 with a sharp implement needle etc Using a suitable cross head screwdriver PZ 1 remove both the visible cross head screws 2 Hold the bottom of the thermometer 6 in one hand and remo...

Страница 17: ...Probes in various specs available on request Reassemble the thermometer in reverse order noting the correct tightening tor que of 0 4 Nm To ensure device is fully water tightness make sure the seal b...

Страница 18: ...erature 30 to 70 C 22 to 158 F Resolution 0 1 C 0 2 F ResolutionTFX430 0 01 C 0 02 F at 100 00 to 199 99 C F and 0 1 C 0 1 F for the rest Measuring precision Series 410 420 0 3 0 3 F Series 430 50 00...