45-TW-X INSTRUCTIONS Page 4
Refer to Diagram #11 Above:
1) Install the Pickups and route the cables to the control cavity keeping
any excess cable under the pickup.
2) Choose an up/down option from diagram #1 or #2 and plug the 45-TW-X
Pickup cable onto the push-pull pot.
3) Route a coax cable from the push/pull pot (H4) to the Pickup buss, Position 1.
Plug the pickup cable of the other EMG into Position 2 of the pickup buss.
4) Plug a coax cable from Position 3 of the Pickup Buss to the VLPF.
Plug a coax cable from the VLPF to the push/pull pot (H1)
5) Plug the output cable from the push/pull pot (H2) to the output jack and push
the connectors onto the T, S, and R terminals of the jack as shown.
6) Plug the RED Wires of the pickups onto the V+ Supply Buss (RED Shroud)
with the RED of the VLPF and the RED wire of the battery clip.
7) Strip the insulation from the switch wires and Insert them into the GREEN
and BLACK Terminal Blocks and tighten the screws with a small screwdriver.
Refer to the B157 Pickup buss instructions enclosed.
8) Put the battery in the insulating foam piece provided and place it securely in
the control cavity.
We suggest that you plug in the instrument and test it before closing the
control cavity.
Refer to Diagram #12 Below:
1) Install the 45-TW-X Pickups and route the cables to the control cavity keeping
any excess cable under the pickup.
2) Choose an up/down option from diagram #1 or #2 and plug the 45-TW-X Pickup
cables onto the push-pull pots.
3) Route a coax cable from each of the push/pull pots (H1) to the VLPF Controls.
4) Plug a coax cable from the Bridge VLPF to the Pickup Buss (Position 1)
Plug a coax cable from the Neck VLPF to the Pickup Buss (Position 2)
5) Plug the output cable from the push/pull pot (H2) to the output jack and push
the connectors onto the T, S, and R terminals of the jack as shown.
6) Plug the RED Wires of the pickups onto the V+ Supply Buss (RED Shroud)
with the RED of the VLPF and the RED wire of the battery clip.
7) Strip the insulation from the switch wires and Insert them into the GREEN
and BLACK Terminal Blocks and tighten the screws with a small screwdriver.
Refer to the B157 Pickup buss instructions enclosed.
8) Put the battery in the insulating foam piece provided and place it securely in
the control cavity.
We suggest that you plug in the instrument and test it before closing the
control cavity.
Diagram #11
2 Pickups (1 EMG + 1-45-TW-X)
Toggle Style Select Switch
Push-Pull Pot as Master Volume
with a Master Tone (VLPF)
FROM NECK PICKUP
FROM 45-TW-X PICKUP
BATTERY
NEG (-)
- 9V +
OUTPUT
T
R
S
OUTPUT CABLE
RED
RED
RED
GROUND
BRIDGE P/U
NECK P/U
OUTPUT
MASTER
VOLUME
MASTER
TONE (VLPF)
NOTE:
REVERSED CONNECTOR
- 9V +
OUTPUT
T
R
S
BATTERY
NEG (-)
NECK TONE
(VLPF)
BRIDGE TONE
(VLPF)
Diagram #12
2 45-TW-X Pickups
2 Push-Pull Pots as Volume controls
(volumes are independent)
2 Active Tones (VLPF)
Toggle Style Switch
GROUND
BRIDGE P/U
NECK P/U
OUTPUT
RED
RED
RED
OUTPUT CABLE
NOTE:
REVERSED
CONNECTORS
NECK
VOLUME
FROM 45-TW-X PICKUP
(NECK)
BRIDGE
VOLUME
FROM 45-TW-X PICKUP
(BRIDGE)