6.3.2
Probe terminal connections
The probe terminals block is permanently fixed to the probe connection
board. The terminals contain plug-in type connectors.
6.3.3
Field Communicator terminal connections
Clips permanently fixed to terminal block, designated as
COMM
.
6.3.4
Junction box conduit entry
M20x1.5,
½
in -14 NPT or
¾
in -14 NPT.
6.3.5
Material of construction
•
Housing: low-copper aluminum alloy
•
Painting: Polyurethane (Rosemount blue color)
•
Cover o-rings: Buna-N 70
•
Conduit plug: stainless steel
•
Terminals: polybutadine terephthalate (PTB) and polycarbonates (PC)
•
Antenna: PBT/PC integrated omni-directional antenna
•
Mounting bracket kit: stainless steel
6.3.6
Weight
Estimated weight 10.14 lb (5 kg)
6.3.7
Enclosure ratings
IP66
6.3.8
Mounting
The Rosemount 4390 Wireless Transmitter is designed for remote mounting
and can be installed on wall, rack, or pipe mounting configuration. For more
information, see
Quick Start Guide
April 2021
42
Emerson.com/Rosemount