Programming and Configuration Items 

1

 

"System On"

 indicates when heating or cooling stage 

 

is energized. 

"System On +2"

 indicates when a second 

 

stage is energized.

2

 

The word "

Hold"

 is displayed when the thermostat is 

 

in the 

HOlD

 mode. "

temp" 

is displayed when 

 

the thermostat is in a 

temporary HOlD

 mode.

3

 

Displays 

"Change Filter" 

when the system has run for 

 

the programmed filter time period as a reminder to

 

 

change or clean your filter.

4  

Displays 

"Set" 

for setpoint when in Run Program mode.

5

 

Displays System Mode 

(Heat, em, auto, Cool, Off)

  

 

or Time in menu mode.

6

 

Displays Fan mode 

(On, auto) "Prog Fan On"

 or    

 

"Run Sched"

 in 

Menu 

mode.

 

 THERMOSTAT QUICK REFERENCE

Home Screen Description

Figure 5 – Home Screen Display

Figure 6 – Programming & Configuration Items

7

 

Displays 

"Run Schedule"

"Schedule"

, or 

"Menu"

.

8

 

Displays 

"Save" 

when 

Cool Savings

tM

 is working.

9

 

Displays 

"Heat Pump" 

when system is configured

 

 

as Heat Pump thermostat.

10

 

Displays 

"Hold"

 in programmable mode when not in 

 

Hold 

mode. Displays 

light Bulb

 in non-program-     

 

mable mode.

11

 

Initially displays 

"auto Sched". 

If Auto Schedule had 

 

been used or disabled, then it displays 

"Cool Savings"

 

 

when in the Cool Mode. Displays 

"Copy"

 in Schedule  

 

mode and 

"Fan"

 in Fan Schedule mode.

12

 

"Call For Service"

 indicates a diagnostic fault in the   

 

heating/cooling system, it does not indicate a fault in the 

 thermostat.

13

 

"Keypad Lockout" 

in Menu mode when selecting key- 

 

pad Lockout or in RUN when a keypad Lockout is active.

Room

Temperature

Setting
Temperature

System

Indicator

Fan
Indicator

Battery Level Indicator 
Indicating the current power level
of the 2 “AA” batteries:
  

   Full power remaining.

  

   Half power remaining

Change           

The batteries should

be replaced at this time with 2 new
premium brand “AA” Alkaline batteries.
(See page 2 for more details)

  

11

10

7

6

5

13

9

1

3

12

8

2

4

Содержание White Rodgers 1F95-0680

Страница 1: ...d or Damper Control Feature Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product co...

Страница 2: ...ING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 1F95 0680 Rear view of thermostat 2 AA Batteries Power Stealing Switches A1 Power Source Mounting Hole Mounting Hole Place Level across Mounting Tabs for appearance only Place Level across Mounting Tabs for appearance only Thermostat Power Method Switch Pos...

Страница 3: ...nstantly in Heat Off Emergency Mode Single Stage and Multi Stage Connections Refer to equipment manufacturers instructions for specific system wiring information This thermostat is designed to operate a single transformer or two transformer system You can configure the thermostat for use with the following systems Single stage SS 1 gas oil or electric Multi stage MS 2 gas oil or electric After wir...

Страница 4: ...tem Diagnostic Module See Module Instructions for details O B Note Dual Fuel option de energizes Heat mode stage 1 compressor when auxiliary heat is energized Note Dual Fuel option de energizes Heat mode stage 1 compressor when auxiliary heat is energized Note Dual Fuel option de energizes Heat mode stage 1 compressor when auxiliary heat is energized Note Dual Fuel option de energizes Heat mode st...

Страница 5: ...ys Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non program mable mode 11 Initially displays Auto Sched If Auto Schedule had been used or disabled then it displays Cool Savings when in the Cool Mode Displays Copy in Schedule mode and Fan in Fan Schedule m...

Страница 6: ...ate for Auxiliary stage when HP 1 or HP 2 is selected above 8 7 7 MENU CL OFF CL On Compressor Lockout Time 9 8 8 MENU Em Heat Cool Off Heat Auto Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off System Mode Configuration with Automatic Changeover capability 10 9 9 MENU dL On dL OFF Selects Display Light On or OFF 11 10 10 MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 L...

Страница 7: ...n select ELE Select GAS if the heating system energizes the fan on a call for heat 3 Select Cool Savings value Selects the amount of adjustment for the Cool Savings feature in Cool mode with 1 1 being the least amount of adjustment and 6 6 being the most amount of adjustment Default value is 3 Cool Savings is an optional energy saving feature that can reduce your cooling costs It is based on the p...

Страница 8: ...re allows you to pro gram a desired comfort temperature into all the program periods along with a 6 set back for night periods of both Heat and Cool programs Factory default is On for both When Heat AS On and Cool AS On are activated while in Heat or Cool mode select desired setpoint temperature and press Auto Schedule This value will be copied into all the morning day and evening program periods ...

Страница 9: ...lter When Change Filter is displayed press MENU or RUN SCHED button to clear the display and restart the time to the next filter change 30 Change UV Lamp This feature allows the thermostat to display the words Change UV Lamp Call for Service of UV bulb after a set time of UV bulb operation This is a reminder to maintain your UV system at optimum level of operation When enabled the factory set inte...

Страница 10: ... to set the Cooling temperatures more than 1 Fahrenheit higher than the heating temperature Em Setting is available only when the thermostat is config ured in HP1 or HP2 mode Manual Operation for Non Programmable Mode Press the SYSTEM button to select Heat or Cool and use the buttons to adjust the temperature to your desired setting After selecting your desired settings you can also press the SYST...

Страница 11: ...turday and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fill in all lines with the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperature...

Страница 12: ...ess Schedule to advance to the next program period 8 Repeat steps 4 through 7 until all of the program times and temperatures are entered for all program periods for that day 9 Press Schedule button to change to the next day and repeat steps 4 through 8 until all program days and peri ods are entered 10 When programming is complete and all of the times and temperatures match your desired heating s...

Страница 13: ...ns at the same time will change the weight for the program period The weight of the thermostat sensor is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sens...

Страница 14: ...ck out from under terminal block Try resetting the thermostat as de scribed above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The the...

Страница 15: ...15 NOTES ...

Страница 16: ...Homeowner Help Line 1 800 284 2925 White Rodgers is a business of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co www white rodgers com www emersonclimate com ...

Отзывы: