66
Unidrive M400 User Guide
Issue Number: 2
6 Basic parameters
6.1 Menu 0: Basic parameters
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
RFC-A
OL
RFC-A
00.001
Minimum Reference Clamp
±VM_NEGATIVE_REF_CLAMP Hz
0.00 Hz
RW Num
US
00.002
Maximum Reference
Clamp
±VM_POSITIVE_REF_CLAMP Hz
50Hz default: 50.00 Hz
60Hz default: 60.00 Hz
RW Num
US
00.003
Acceleration Rate 1
±VM_ACCEL_RATE s
5.0 s
RW Num
US
00.004
Deceleration Rate 1
±VM_ACCEL_RATE s
10.0 s
RW Num
US
00.005
Drive Configuration
AV (0), AI (1), AV Preset (2), AI Preset (3), Preset (4),
Keypad (5), Keypad Ref (6), Electronic Pot (7), Torque
Control (8), Pid Control (9)
AV (0)
RW Txt
PT US
00.006
Motor Rated Current
±VM_RATED_CURRENT A
Maximum Heavy Duty
Rating
(11.032) A
RW Num
RA
US
00.007
Motor Rated Speed
0.0 to 80000.0 rpm
50Hz
default:
1500.0 rpm
60Hz
default:
1800.0 rpm
50Hz
default:
1450.0 rpm
60Hz
default:
1750.0 rpm
RW Num
US
00.008
Motor Rated Voltage
±VM_RATED_VOLTAGE V
110V drive: 230 V
200V drive: 230 V
400V drive 50 Hz: 400 V
400V drive 60 Hz: 460 V
575V drive: 575 V
690V drive: 690 V
RW Num
RA
US
00.009
Motor Rated Power Factor
0.00 to 1.00
0.85
RW Num
RA
US
00.010
User Security Status
Menu 0 (0), All Menus (1),
Read only Menu 0 (2), Read only (3),
Status Only (4), No Access (5)
Menu 0 (0)
RW Txt
ND NC PT
00.012
Input Logic Polarity
Negative Logic (0) or Positive Logic (1)
Positive Logic (1)
RW Txt
US
00.015
Jog Reference
0.00 to 300.00 Hz
1.50 Hz
RW Num
US
00.016
Analog Input 1 Mode
4-20 mA Stop (-6), 20-4 mA Stop (-5),
4-20 mA Low (-4), 20-4 mA Low (-3),
4-20 mA Hold (-2), 20-4 mA Hold (-1),
0-20 mA (0), 20-0 mA (1), 4-20 mA Trp (2),
20-4 mA Trp (3), 4-20 mA (4),
20-4 mA (5), Voltage (6)
Voltage (6)
RW Txt
US
00.017
Bipolar Reference Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
00.018
Preset Reference 1
±VM_SPEED_FREQ_REF Hz
0.00 Hz
RW Num
US
00.025
User Security Code
0 to 9999
0
RW Num ND NC PT US
00.027
Power-up Keypad Control
Mode Reference
Reset (0), Last (1), Preset (2)
Reset (0)
RW Txt
US
00.028
Ramp Mode Select
Fast (0), Standard (1), Std boost (2),
Fast boost (3)
Standard (1)
RW Txt
US
00.029
Ramp Enable
Off (0) or On (1)
On (1)
RW
Bit
US
00.030
Parameter Cloning
None (0), Read (1), Program (2),
Auto (3), Boot (4)
None (0)
RW Txt
NC
US
00.031
Stop Mode
Coast (0), Ramp (1), Ramp dc I (2), dc I (3), Timed dc I
(4), Disable (5), No Ramp (6)
Ramp (1)
RW Txt
US
00.032
Dynamic V to F Select /
Flux Optimization Select
0 to 1
0
RW Num
US
Menu 0 is used to bring together various commonly used parameters for basic easy set up of the drive. All the parameters in Menu 0 appear in other
menus in the drive (denoted by {…}). Menus 22 can be used to configure the parameters in Menu 0.
Содержание Unidrive M400
Страница 197: ......
Страница 198: ...0478 0044 02 ...