5.8 Parameter access level and security
The parameter access level determines whether the user has access to
Menu 0 only or to all the advanced menus (Menus 1 to 22) in addition to
Menu 0.
The User Security determines whether the access to the user is read
only or read write.
Both the User Security and Parameter Access Level can operate
independently of each other as shown in Table 5-7.
Table 5-7 Parameter access level and security
The default settings of the drive are Parameter Access Level Menu 0
and user Security Open i.e. read / write access to Menu 0 with the
advanced menus not visible.
5.8.1 User Security Level / Access Level
The drive provides a number of different levels of security that can be set
by the user via
User Security Status
(00.010); these are shown in the
table below.
5.8.2 Changing the User Security Level /Access
Level
The security level is determined by the setting of Pr
00.010
or Pr
11.044
.
The Security Level can be changed through the keypad even if the User
Security Code has been set.
5.8.3 User Security Code
The User Security Code, when set, prevents write access to any of the
parameters in any menu.
Setting User Security Code
Enter a value between 1 and 9999 in Pr
00.025
and press the
button; the security code has now been set to this value. In order to
activate the security, the Security level must be set to desired level in
Pr
00.010
. When the drive is reset, the security code will have been
activated and the drive returns to Menu 0. The value of Pr
00.025
will
return to 0 in order to hide the security code.
Unlocking User Security Code
Select a parameter that need to be edited and press the
button,
the display will now show ‘Co’. Use the arrow buttons to set the security
code and press the
button. With the correct security code
entered, the display will revert to the parameter selected in edit mode.
If an incorrect security code is entered, the following message ‘Co.Err’ is
displayed, and the display will revert to parameter view mode.
Disabling User Security
Unlock the previously set security code as detailed above. Set Pr
00.025
to 0 and press the
button. The User Security has now been
disabled, and will not have to be unlocked each time the drive is
powered up to allow read / write access to the parameters.
5.9 Displaying parameters with non-
default values only
By selecting 'diff.d' in Pr
mm.000
(Alternatively, enter 12000 in
Pr
mm.000
), the only parameters that will be visible to the user will be
those containing a non-default value. This function does not require a
drive reset to become active. In order to deactivate this function, return
to Pr
mm.000
and select 'none' (alternatively enter a value of 0). Please
note that this function can be affected by the access level enabled, refer
to section 5.8
Parameter access level and security
further information regarding access level.
5.10 Displaying destination parameters only
By selecting 'dest' in Pr
mm.000
(Alternatively enter 12001 in
Pr
mm.000
), the only parameters that will be visible to the user will be
destination parameters. This function does not require a drive reset to
become active. In order to deactivate this function, return to Pr
mm.000
and select 'none' (alternatively enter a value of 0).
Please note that this function can be affected by the access level
enabled, refer to section 5.8
Parameter access level and security
page 20 for further information regarding access level.
User
security
status
(00.010)
Access level
User
security
(00.025)
Menu 0
status
Advanced
menu status
0
Menu 0
None
RW
Not visible
1
All Menus
None
RW
RW
2
Read-only
Menu 0
Open
RW
Not visible
Closed
RO
Not visible
3
Read-only
Open
RW
RW
Closed
RO
RO
4
Status only
Open
RW
RW
Closed
Not visible
Not visible
5
No access
Open
RW
RW
Closed
Not visible
Not visible
User Security
Status
(Pr 00.010)
Description
LEVEL.0 (0)
All writable parameters are available to be edited but
only parameters in Menu 0 are visible
ALL (1)
All parameters are visible and all writable parameters
are available to be edited
r.only.0 (2)
Access is limited to Menu 0 parameters only. All
parameters are read-only
r.only.A (3)
All parameters are read-only however all menus and
parameters are visible
Status (4)
The keypad remains in status mode and no
parameters can be viewed or edited
no.acc (5)
The keypad remains in status mode and no