TS1__35038_EN_R05.doc 

8 / 8 

10.08.2011

 

Accessories 

 

Universal mounting bracket 

803 801 (incl. screws) 

 

Mounting bracket angle 

803 799 (incl. screws) 

 

Extension bracket 

803 800 (incl. screws) 

 

Insulation console 

803 777 

room thermostats: standard 

14

Ø 5,5

6

20

28

R1/2

19 27 

SW 27 

 

Capillary tube holder,

5 pcs 

803 778 

frost monitors: standard

Capillary tube gland, brass, 

R½ 

For sensors A + C 

803 807 

Mounting angle for TS1-G, -H

803 805 

ALCO CONTROLS is not to be held responsible for erroneous literature 
regarding capacities, dimensions, applications, etc. stated herein. 
Products, specifications and data in this literature are subject to change 
without notice. The information given herein is based on technical data 
and tests which  ALCO CONTROLS believes to be reliable and which 
are in compliance with technical knowledge of today. It is intended only 
for use by persons having the appropriate technical knowledge and 

skills, at their own discretion and risk. Our products are designed and 
adapted for fixed locations. For mobile applications failures may occur.  
The suitability for this has to be assured from the plant manufacturer 
which may include making appropriate tests.  Since conditions of use 
are outside of ALCO'S control we can not assume any liability for 
results obtained or damages occurred due to improper application.   
This document replaces all earlier versions. 

 

Emerson Electric GmbH & Co OHG 
ALCO CONTROLS 
Postfach 1251 
Heerstraße 111 
D-71332 Waiblingen   
Germany 
Phone ...49-7151-509-0   
Fax ...49-7151-509-200 
 

www.emersonclimate.eu

Benelux 
Germany, Austria & Switzerland 
France, Greece, Maghreb 
Italia 
Spain & Portugal 
UK & Ireland 
Sweden, Denmark, Norway & Finland 
Eastern Europe & Turkey 
Poland 
Russia & Cis 
Balkan 
Romania 
Ukraine 

Phone: 

+31 (0)77 324 0 234 
+49 (0)6109 6059 -0 
+33 (0)4 78 66 85 70 
+39 02 961 781 
+34 93 41 23 752 
+44 (0) 1635 876 161 
+49 (0)2408 929 0 
+49 (0)2408 929 0 
+48 (0)22 458 9205 
+7 495 981 9811 
+385 (0) 1560 38 75 
+40 364 73 11 72 
+38 44 4 92 99 24 

Fax: 

+31 (0)77 324 0 235 
+49 (0)6109 6059 40 
+33 (0)4 78 66 85 71 
+39 02 961 788 888 
+34 93 41 24 2 
+44 (0) 1635 877 111 
+49 (0)2408 929 528 
+49 (0)2408 929 525 
+48 (0)22 458 9255 
+7 495 981 9816 
+385 (0) 1 560 3879 
+40 364 73 12 98 
+38 44 4 92 99 28 

12

,6

25

,2

12

,6

82

65 

50,5
25,2

25

,2

25

,2

12

,6

5

12

0

4

41

40

18

25

12

,5

Ø 4,5

25

30

25

25

25

M4

12

,5

Ø 4,5

44

70 ±0,2

4,8

3

0

1

5

,5

83

3

0

1

1

4

8

Содержание TS1 Series

Страница 1: ... delivered in three main housing variants top operated front operated and flush mounted Top operated controls have adjustment spindles at the top and a display scale indicating temperature setpoint and differential at the front A knob which may be permanently plugged onto one of the adjustment spindles comes with every control Frost monitors and room thermostats are derivatives of top operated the...

Страница 2: ...spond faster to temperature changes than adsorption and liquid charges Adsorption charge sensor type F Adsorption charged sensor types operate on the basis of a temperature dependent adsorption material which is located inside the bulb only Therefore these sensor types always respond to temperature changes at the bulb only This makes them suitable to applications where it is not always defined whi...

Страница 3: ... again Manual reset low pressure contact function Manual reset high temperature On increasing temperature above the upper setpoint contacts 1 2 open contacts 1 4 close and latch Only on falling temperature below lower setpoint and after pressing the manual reset button contacts 1 4 will open and contacts 1 2 will close again Manual reset high temperature contact function For operational safety all...

Страница 4: ...30 V DC 3A 24 V DC 6A 12 V DC Vibration resistance 4 g 10 1000 Hz Motor rating UL FLA 24A 120 240V AC Approvals Locked rotor UL LRA 144A 120 240V AC Low Voltage Directive all models Bellows heater sensor types A E P 73 23 EWG 93 68 EWG EN 60947 1 60947 5 1 60730 2 9 CE Label not for frost monitors function C or D option 82 k 230V AC DC 12V 24V rating Germanic Lloyd standard models Materials when u...

Страница 5: ...l dimensions and drawings TS1 Axx Bxx Cxx Dxx TS1 Exx Fxx TS1 Gxx Hxx Sensor type A Vapour charge 2 m capillary with bulb Sensor type P Vapour charge 2 m capillary 6m with function C or D Sensor type E Vapour charge coil 0 m Sensor type F Adsorption charge 2 m capillary with bulb 54 70 Ø 9 2 2 5 Ø 9 5 70 Ø 22 ...

Страница 6: ... 351 800 30 35 2 8 20 35 5 0 and Defrost and Universal Thermostat 100 Adsorption bulb TS1 A5F 4 458 400 20 60 3 10 10 35 30 Thermostats with Off Switch TS1 B1A 4 366 700 45 10 55 18 20 2 m TS1 B2A 4 366 800 30 15 1 5 16 36 1 6 150 Vapour capillary TS1 B3A 4 366 900 10 35 23 3 2 and TS1 B4F 4 367 000 30 35 2 8 20 35 5 0 100 Adsorption bulb Room Thermostats TS1 Top Operated with coil type sensor Roo...

Страница 7: ...pe sensor Room Thermostats without Off Switch including insulation console TS1 E1E 4 365 300 45 10 2 16 55 18 20 0 m TS1 E2E 4 356 800 30 10 1 5 15 36 4 2 70 Vapour coil TS1 E3E 4 356 900 10 25 1 5 15 23 20 18 Room Thermostats with Off Switch including insulation console TS1 F1E 4 368 000 45 10 2 16 55 18 20 TS1 F2E 4 368 100 30 10 1 5 15 36 4 2 70 Vapour 0 m TS1 F3E 4 368 200 10 25 1 5 15 23 20 1...

Страница 8: ...ations failures may occur The suitability for this has to be assured from the plant manufacturer which may include making appropriate tests Since conditions of use are outside of ALCO S control we can not assume any liability for results obtained or damages occurred due to improper application This document replaces all earlier versions Emerson Electric GmbH Co OHG ALCO CONTROLS Postfach 1251 Heer...

Отзывы: