Emerson TARTARINI RP Series Скачать руководство пользователя страница 7

Type RP

7

aDjuSTmENT

To change the outlet pressure, turn the adjusting nut (key. 1) 

clockwise to increase outlet pressure or counter clockwise to 

decrease pressure.
Monitor the outlet pressure with a test gauge during the 

adjustment.

ShuTDOWN

!

WarNING

To avoid personal injury resulting from 

sudden release of pressure, isolate the 

regulator from all pressure before attempting 

disassembly and release trapped pressure 

from the equipment and pressure line.
In case of disassembly of main pressure re-

taining parts for checks and maintenance pro-

cedures, external and internal tightness tests 

have to be done according applicable codes.

PErIODICaL ChECKS

CauTION

It is recommended that checks be made 

periodically on the efficiency of the regulator 

and pilots. 

regulator Checking

Slowly close the outlet cut-off valve and check pressure in 

the length of pipe between the regulator and the valve.
If the system is functioning properly, an increase in outlet 

pressure will be noticed due to lock-up pressure, after which 

pressure will stabilize.
If, on the contrary, outlet pressure continues increasing, the 

system is not functioning properly due to improper valve disc 

tightness. In this case, close the valve located upstream of 

regulator and carry out maintenance procedures. 

Slam-Shut Controller Checking

 (if installed)

See the Instruction Manual 0048EN-OS66-IM.

maINTENaNCE (SEE FIGurE 6)

!

WarNING

all maintenance procedures must be 

carried out only by qualified personnel. If 

necessary, contact our technical support 

representatives or our authorized dealers. 

The regulator and it’s pressure accessories are subject 

to normal wear and must be inspected periodically and 

replaced if necessary.

The frequency of inspection/checks and replacement 

depends upon the severity of service conditions and 

according to applicable National or Industry codes, 

standards and regulations/recommendations.

In accordance with applicable National or Industry codes, 

standards and regulations/recommendations, all hazards 

covered by specific tests after final assembling before 

applying the CE marking, shall be covered also after every 

subsequent reassembly at installation site, in order to ensure 

that the equipment will be safe throughout its intended life.

Before proceeding with any maintenance work, shutoff the 

gas upstream and downstream from the regulator, also 

ensure that there is no gas under pressure inside the body 

by loosening the upstream and downstream connections.

upon completion, check for leaks using suds.

General maintenance

a. Remove the adjusting screw (key 1), the ring nut (key 2), 

the plate (key 4) and the springs (key 5 and  6); unscrew 

the screws (key 48) and take off the upper cover (key 7).

b. Dismount the diaphragm group, unscrewing the nut 

(key 8), take off the plates (key 49 and 51), replace the 

diaphragm (key 47) and the gasket (key 46).

c.  unscrew the screw (key 60) and dismount the lower cover 

(key 42) from the body (key 40).

d. unscrew the screw (key 20), dismount the pad holder 

(key 21), replace the pad (key 22) and the gasket (key 41).

e. unscrew the screw (key 52), take off the levers group, 

and check the parts and if you find any wear sign, replace 

them all. 

f. 

Versions without shut-off device:

 

unscrew the plug (key 68), dismount the filter (key 37) 

and the seat (key 38), if it’s worn o scored replace it. 

Replace the O-ring (key 34 and 39).

Versions with shut-off device:

  

remove impulse line (A) and loosen dowels (G) and 

remove the OS/66 slam-shut controller. unscrew the 

plug (key 29), dismount the filter (key 37) and the seat 

(key 38), if it’s worn o scored replace it. Replace the 

O-ring (key 34 and 39).

relatching unit maintenance

 (if installed)

a. Trigger the OS/66 slam-shut controller and remove 

impulse line (A).

b. Loosen dowels (G) and remove the OS/66.

c.  unscrew the plug (key 29) and check stem (key 28). 

If worn, replace the stem by unscrewing pad-holder 

(key 33) and dismantling the various components.

Содержание TARTARINI RP Series

Страница 1: ...1 66 This product has been designed to be used with fuel gases of 1st and 2nd family according to EN 437 and with other non aggressive and non fuel gases For any other gases other than natural gas please contact your local sales agent The following versions are available RP 011 RP 022 RP 033 Regulator RP 011 66 RP 022 66 RP 033 66 Regulator with slam shut The standard gas pressure devices regulato...

Страница 2: ...nections RP 011 1 x 1 1 4 BSP RP 022 1 1 4 x 2 BSP RP 033 2 x 3 BSP Flanged Connections RP 011 FS DN 25 x 32 PN 16 25 40 CL150 CL300 RP 022 FS DN 32 x 50 PN 16 25 40 CL150 CL300 RP 033 FS DN 50 x 80 PN 16 25 40 CL150 CL300 Warning The pressure temperature limits indicated in this instruction manual or any applicable standard or code limitation should not be exceeded Maximum Operating Inlet Pressur...

Страница 3: ...any possible external ignition source inside the equipment due to mechanical generated sparks drainage to safe area via drain lines of foreign materials if any by inflow of fuel gas with low velocity in the pipe work 5m sec In any case provisions of Directive 1999 92 EC and 89 655 EC shall be enforced by gas pressure regulating measuring station installation s end user with a view to preventing an...

Страница 4: ...Inlet Outlet RP 011 1 1 1 4 50 280 120 206 102 135 185 195 6 5 RP 011 66 1 1 1 4 280 120 206 102 135 185 195 125 7 7 RP 022 1 1 4 2 50 300 120 266 106 135 185 200 10 5 RP 022 66 1 1 4 2 300 120 266 106 135 185 200 125 11 7 RP 033 2 3 70 300 120 266 120 160 230 270 13 RP 033 66 2 3 300 120 266 120 160 230 270 142 14 2 I1 Flanged connections PN 16 25 40 I2 Flanged connections CL 300 DIMENSIONS and w...

Страница 5: ...he valve disc the antagonist action of the adjustment springs tends to open it Under normal conditions the balance between these antagonist actions positions the valve disc in such a way as to ensure a constant pressure and therefore the downstream capacity Upon any capacity variation tending to cause an increase or decrease of pressure in relation to the pre set pressure the moving unit reacts an...

Страница 6: ...id standards the gas shall be cleaned by proper filters separators scrubbers to avoid any technical reasonable hazard of erosion or abrasion for pressure containing parts Pressure equipment in subject shall be installed in non seismic area and hasn t to undergo fire and thunderbolt action Clean out all pipelines before installation of the regulator and check to be sure the regu lator has not been ...

Страница 7: ...ndustry codes standards and regulations recommendations In accordance with applicable National or Industry codes standards and regulations recommendations all hazards covered by specific tests after final assembling before applying the CE marking shall be covered also after every subsequent reassembly at installation site in order to ensure that the equipment will be safe throughout its intended l...

Страница 8: ... Check for leaks using suds Spare parts Spare parts storage shall be done by proper procedures according to national standard rules to avoid over aging or any damage Troubleshooting Table 3 General Troubleshooting for RP Series SYMPTOMS Cause ACTIONS The regulator does not open Lack of incoming gas Check the station feeding The slam shut controller has not been reset Manually reset the slam shut c...

Страница 9: ...g 37 Filter 38 Seta 39 O ring 40 Body 41 Gasket 42 Lower cover 43 Pin 44 Nut 45 Washer 46 Gasket 47 Diaphragm 48 Screw 49 Plate 50 Plate 51 Plate 52 Screw 53 Washer 54 Support 55 Lever 56 Needle 57 Needle 58 Fork lever 59 Label 60 Screw 61 Plate 62 O ring 63 Hub 64 Flange 65 Flange 66 Hub 67 O ring 68 Plug 69 Plug Rubber parts marked with are supplied in the spare parts kit recommended as stock To...

Страница 10: ...Type RP 10 Figure 6 RP Series Regulator continued LM 1391 59 58 57 56 55 60 54 53 52 ...

Страница 11: ...Type RP 11 Figure 6 RP Series Regulator continued LM 1391 OUTLET PRESSURE 2 BAR VERSION 48 47 51 50 49 61 69 68 34 VERSION WITHOUT SLAM SHUT 64 63 62 67 65 66 FLANGED VERSION ...

Страница 12: ...ers McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Africa Dubai United Arab Emirates Tel 971 4811 8100 For further information visit www emersonprocess com regulators Natural Gas Technologies Emerson Process Management Regulator Technologies Inc USA Headquar...

Отзывы: