SPS 4001B
SPECIFICATIONS
NOTES
(1) Hazardous area option requires the addition of a Z-purging system by the owner.
(2) Reference air is recommended with 9 ft (2.74 m) and 12 ft (3.66 m) long probes. Reference air is also
recommended when ambient air may not contain the normal 20.95% O
2
, such as when the probe is
mounted into a positive pressure duct with leaks or where there is a process unit nearby with leaks.
(3) Customer to provide piping from remote SPS 4001B to probe.
(4) External current limiting device must be provided by customer.
(5) If contacts are used to drive relay coils, a reverse blocking (flyback) diode must be installed on the input
to the relay coil. Relay and diode to be provided by customer.
Specifications
SPS 4001B Assembly
Part Number
6A00175G01
Mounting
Wall mount
Materials of Construction:
Enclosure
Fiberglass
Manifold
Aluminum with 1/4 in. NPT ports
Pneumatic tubing - Low
Pressure
Buna N with overbraid
Pneumatic tubing - High
Pressure
Impolene
Assembly hardware
Galvanized and stainless steel
Humidity range
5 - 95% relative humidity, non condensing
Ambient temperature range
-40° to 149°F (-40° to 60°C) with optional heater
-25° to 149°F (-5° to 60°C)
Enclosure protection
NEMA 4 (IP66)
Hazardous area option
(1)
Z-purge (by owner)
Electrical entries
1/2 in. NPT (0.875 in. with gland)
Input power
90 to 250 VAC ±10%, 50/60 Hz
Power consumption
15VA maximum
External electrical noise
EN 61326-1 class A
Handshake signal to/from
Oxymitter 4000
(self-powered)
5V (5mA maximum)
Cal initiate input from control
room:
Internally 5V powered
In-Cal Relay Contact
(4)(5)
5 to 30 VDC, 100 mA, Form A (SPST)
Cal Failed Relay Contact
(4)(5)
5 to 30 VDC, 100 mA, Form A (SPST)
Cabling distance between SPS
4001B and Oxymitter 4000
Maximum 1000 ft (303 m)
Piping distance between
SPS 4001B and
Oxymitter 4000
(2) (3)
Maximum 300 ft (91 m)
Instrument Air
Maximum 100 psi (689 kPa)
Calibration Gases
25 psi (172 kPa)
Approximate shipping weight
10 lbs (4.5 kg)
Pollution degree
2
Overvoltage Category
II
Certification
General Purpose
APPROVED
C
US
Содержание SPS 4001B
Страница 2: ......
Страница 4: ......
Страница 6: ...Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 SPS 4001B TOC 2 ...
Страница 16: ...SPS 4001B 1 8 Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 ...
Страница 34: ...SPS 4001B 4 8 Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 ...
Страница 42: ...SPS 4001B 6 4 Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 ...
Страница 66: ...SPS 4001B A 24 Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 ...
Страница 68: ...SPS 4001B B 2 Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 ...
Страница 70: ...Instruction Manual IM 106 340AC 1 Rev 1 2 January 2007 SPS 4001B Index 2 ...