11. Check that Pr
15.01
shows the correct code for the SM-I/O 24V Protected: 205.
12. Power the drive down and back up. The Solutions Module is now ready for
programming.
13. If the checks in step 10 and step 11 fail, either the Solutions Module is not fully
inserted, or it is faulty.
14. If a trip code is now present refer to
.
4.2
Terminal descriptions
Figure 4-5 SM-I/O 24V Protected terminals
Table 4-1 Terminal descriptions
17-way 3.81mm pluggable screw connector.
*Digital input only with Commander SK
**Not available on Commander SK
If the SM-I/O 24V Protected is changed for another type of Solutions Module, the drive
will trip as in step 8. Follow the above procedure.
NOTE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Provide fuse or other over-current protection in the relay circuit.
WARNING
Term
Function
1
0V common
2
0V common
3
Digital I/O 1
4
Digital I/O 2
5
Digital I/O 3
6
Digital I/O 4*
7
Digital input 5
8
Digital input 6
9
Digital input 7
10
Analogue output 1
11
0V common
12
Analogue output 2
13
0V common
14
Relay 1 contact 1
15
Relay 1 contact 2
16
Relay 2 contact 1**
17
Relay 2 contact 2**